EasyManua.ls Logo

STIEBEL ELTRON Accelera 300 - Connect the power cable to the mains terminal; WARNING Electric shock

STIEBEL ELTRON Accelera 300
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
WWW.STIEBEL-ELTRON-USA.COM ACCELERA 300 | 23
INSTALLATION
INSTALLATION
CAUTION :
Risk of electric shock
Use copper conductors only
11
10
4
6
3
1
16
15
13
12
8
7
14
9
5
26_03_01_1406
2
284759-34684
CAUTION :
Risk of electric shock
Use copper conductors only
1 Capacitor
2 Cable entry into the water heater casing
3 Strain relief (cable clamp)
4 Mains terminal
5 Frost monitor
6 Heat pump control thermostat
7 Fan motor
8 Heat pump terminal
9 Thermostat, booster heater
10 High limit safety cut-out, booster heater,
manual reset (see 14.1.1)
11 Booster heater
12 Sacrificial anode
13 Safety pressure limiter, manual reset,
(see 14.1.2)
14 Condensate pan drain
15 Compressor
16 Compressor motor protection (Klixon),
delay auto reset (see 14.1.3)
» Pull the power cable through the cable entry into
the water heater interior.
» Route the power cable through the strain relief
(cable clamp).
» Connect the power cable to the mains terminal in
accordance with the wiring diagram (see chapter
16.2 "Wiring Diagram". L1, L2 and ground).
WARNING Electric shock
Risk of injury through inadequate grounding.
» Ensure that the water heater is correctly
grounded in accordance with the
requirements at the place of installation.
The ground conductor of the power cable
must be connected to the terminal marked G
or Earth.
Air flow
Air flow

Table of Contents

Other manuals for STIEBEL ELTRON Accelera 300

Related product manuals