Warning
A temperature and pressure relief valve
must be fitted to the clearly marked
socket. The valve drain outlet pipe
must not be sealed or blocked, and the
valve easy gear is to be operated
at least once every six month.
28
0
5
58-
34684
Relief valve
Plumber:
The relief valve supplied in the
carton must be fitted to this
socket.
KW Eintritt
CW Inlet
2
80303
-
346845
4
2
6
1
7
3
5
26_03_01_1355
3
1 Information label "Condensate drain"
2 Information label "Risk of scalding"
3 Information label "Connection"
4 Information label "Hot water outlet"
5 Information label "Relief valve"
6 Information label "Relief valve installation location"
7 Information label "Cold water inlet"
Power supply
Disconnect power supply
before opening the cover.
2
80
5
56-3
468425
Type: Accelera 300/WHP 300
Heat pump:
PN (Air 42° / Water 60°):
IN (Air 42° / Water 60°):
Type of Refrigerant:
Refrigerant charge:
Max. operating pressure:
Lock rotor current:
MCA:
Rated load compressor:
Motor fan:
Order-No.: 222423
DHW-cylinder:
Additional heating element:
Max. operating pressure:
Max. operating temperature:
Type of cylinder material:
Cylinder capacity:
Test pressure storage tank:
Observe the installation manual! Tested for leaks!
Made in Germany
No.: 8443 / 005204
Voltage / Frequency:
Breaker:
P (rated power input):
Maximum allowable ratings
Protection class:
Nmax
Single phase 220-240 V, 50/60 Hz
15 amp.
2200 W, 9.17 A
IP 24
*222423844300520415*
1690 W
87 psi /600
kPa
168.8 °F /76 °C
Glass lined steel
80.044 Gal /303 l
130.5 psi / 900 kPa
0.5 kW
2.17 A
R134A
1.9842 Lb. /900 g
348.1 psi /2.4 MPa
13.4 A
10.4 A
2.3 A
38 W
STIEBEL ELTRON INC
17 West Street
West Hatfield, MA 01088
USA
282209-35237
DE: Enthält vom Kyoto - Protokoll erfasste fluorierte Treibhausgase - hermetisch geschlossenes System.
GB: Contains fluorinated greenhouse gases covered by the Kyoto Protocol - hermetically sealed.
FR: Comprend les gaz à effet de serre fluorés enregistrés par le protocole de Kyoto - systèmes hermétiquement scellés.
NL: Bevat gefluoreerde broeikasgassen die onder het Kyoto-protocol vallen - hermetisch gesloten systeem.
SE: Innehåller av Kyoto - protokollet registrerade flourerande växthusgaser i hermetiskt förslutna system.
PL: Zawiera fluorowane gazy cieplarniane ujęte w Protokole z Kioto - hermetycznie zamknięty układ.
CZ: Obsahuje fluorizované skleníkové plyny, obsažené v Kjótském protokolu - hermeticky uzavřený systém.
ES: Sistema herméticamente cerrado que contiene gases de efecto invernadero mencionados en el protocolo de Kioto.
DK: Indeholder fra Kyoto-protokollen registrerede, fluorerede drivhusgasser – hermetisk lukket system.
NO: Inneholder fluorerte drivhusgasser som omfattes av Kyotoprotokollen - hermetisk lukket system.
FI: Sisältää Kioton sopimuksen alaisia fluorattuja kasvihuonekaasuja - ilmatiiviisti suljettu järjestelmä.
284436-34741
BG: Съдържа посочените в Протокола от Киото флуорирани парникови газове - херметически затворена система.
HU: A Kiotói Jegyzıkönyv szerinti fluortartalmú üvegházhatású gázokat tartalmaz - hermetikusan zárt rendszer.
IT: Contiene gas fluorurati ad effetto serra disciplinati dal protocollo di Kyoto - Impianto ermeticamente chius.
RO: Conține un sistem închis ermetic contra emisiei de gaze fluorine monitorizat de protocolul Kyoto.
8
11
26_03_01_1356
10
9
8 Information label "Power connection"
9 Type plate
10 Information label "Fluorated gases"