INSTALLATION
Water heater shutdown
16 | DCE Premium www.stiebeleltronamericas.com
D0000082937
f Connect the programming unit connecting cable plug to the
PCB.
Note
It is essential to plug the connecting cable from the
programming unit into the PCB before switching on the
power. Otherwise, the programming unit will not func-
tion.
D0000073642
f Hook the water heater cover into the water heater back panel
at the top rear. Pivot the water heater cover downwards.
Check that the water heater cover is securely seated at both
top and bottom.
f Secure the water heater cover with the screw.
f Remove the protective film from the user interface.
D0000053281
f Switch on the power supply.
f Ensure that the programming unit is functioning correctly.
11.3.2 Water heater handover
f Explain the water heater functions to users and familiarize
them with how it works.
f Make the user aware of potential dangers, especially the risk
of scalding.
f Hand over the instructions.
11.4 Operation with preheated water
You can limit the maximum inlet temperature by installing a cen-
tral thermostatic valve.
Use a thermostatic valve for central premixing, for example when
operating an instantaneous water heater with preheated water.
For use in shower operation, the valve must be set to a maximum
of 131 °F (55 °C).
11.5 Recommissioning
!
Material losses
To ensure that the Direct Coil
™
heating system is not dam-
aged following an interruption to the water supply, the
water heater must be restarted by taking the following
steps.
f Shut off power to the unit at the breaker panel by
making sure that connected circuit breakers are
“OFF” to avoid any danger of electric shock.
f Open and close the tap at least five times for three
minutes total, until the water heater and its up-
stream cold water inlet line are free of air.
f Switch the power back ON at the breaker panel.
12. Water heater shutdown
f Shut off power to the unit at the breaker panel by making
sure that connected circuit breakers are “OFF” to avoid any
danger of electric shock.
f Drain the water heater (see section 16.1, “Draining the water
heater”, pg. 20).
13. Alternative installation methods
WARNING Electrocution
Before performing any work on the appliance, discon-
nect all poles from the power supply.
13.1 Concealed installation, electrical connection
from below
D0000079465
1
1 Cable grommet
f Break out the required aperture in the back panel for the
power cable (for positions, see section 17.1, “Dimensions and
connections”, pg. 21). De-burr any sharp edges with a file.
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
f Install the water heater and connect the power cable to
the wiring block as described in section 10.1, “Standard
non-concealed installation”, pg. 14.
f Seal the factory-fitted cable grommet with the plug included
in the standard delivery.