30 | DEL SL electronic LCD www.stiebel-eltron.com
INSTALLATION
Installation
26�02�02�1334
21
1 Plastic profile washer
2 Flow limiter
Note
Install the blue flow limiter (7.5l/min) as standard.
Use the brown flow limiter (12l/min) in the follow-
ing instances:
- With an increased cold water inlet temperature, e.g.
in the case of water preheated by solar energy.
- When using the appliance for showering.
With low water pressure.The pressure drop can be
reduced by replacing the flow limiter with the plastic
profile washer provided.
Installing the appliance
26�02�02�1336
For easy installation, push the cable grommet of the upper
electrical connection into the back panel from behind.
Remove the transport plugs from the water connections.
Remove the fixing toggle from the upper part of the back
panel.
Route the power cable through the cable grommet from be-
hind, until the power cable rests against the cable sheath.
Align the power cable.
If the cross-section is >6mm², enlarge the hole in the cable
grommet.
Press the appliance over the threaded stud of the wall
mounting bracket. When doing so, push through the soft
seal in the back panel of the appliance. If necessary, use a
screwdriver.
Push the fixing toggle on to the threaded stud of the wall
mounting bracket.
Push the back panel of the appliance on to the wall. Turn the
fixing toggle 90° clockwise to lock the appliance in place.
24
19
3 Nm
5 Nm
D0000056244
Fit the pipes with flat gaskets onto the twin connectors.
Connecting the power supply
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Connection to the power supply is only permissible in the
form of a permanent connection in conjunction with the
removable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
!
Damage to the appliance and environment
Observe the type plate. The specified voltage must match
the mains voltage.
26�02�02�1122�
Connect the power cable to the mains terminal (see chapter
"Specification/ Wiring diagram"). The specified voltage must
match the mains voltage.