INSTALLATION
Commissioning
ENGLISH
www.stiebel-eltron.com DHB-E LCD | 31
Pull the cable grommet over the cable sheath of the power
cable. For large cable cross-sections, enlarge the hole in the
cable grommet if necessary.
D0000053274
Remove the transport protection plugs from the appliance
pipe connections.
Bend the power cable 45° upwards.
Route the power cable and cable grommet through the back
panel from the rear.
Install the appliance on the threaded studs of the wall
mounting bracket.
Press the back panel firmly into place, aligning it correctly.
Lock the fixing toggle by turning it 90° clockwise.
Pull the cable grommets into the back panel, until both lock-
ing tabs engage.
24
19
3 Nm
5 Nm
D0000056244
Fit the pipe connections with flat gaskets onto the water
connections.
Open the 3-way ball shut-off valve or the shut-off valve in the
cold water supply line.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection in conjunction with the re-
movable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
!
Material losses
Observe the type plate. The specified rated voltage must
match the mains voltage.
Connect the power cable to the mains terminal.
Fitting the lower back panel section
D0000053275
1
1 Diffuser on lower back panel
Fit the lower back panel section into the back panel. Check
that both locking tabs are engaged.
Align the mounted appliance by undoing the fixing toggle,
aligning the power supply and back panel, and then re-tight-
ening the fixing toggle. If the back panel does not sit flush
against the wall, you can secure the appliance at the bottom
with an additional screw.
!
Material losses
Do not bend the diffuser on the lower back panel when
installing.
11. Commissioning
11.1 Preparation
18 21 24
43 50 55 60
11 13
43 50 55 60
D0000076843
1
3
2
1 Jumper for anti-scalding protection setting
2 Jumper for connected load: DHB-E 11/13 LCD
3 Jumper for connected load: DHB-E 18/21/24 LCD
Internal anti-scalding protection via jumper slot
Jumper position Description
43 Forexample, nurseries, hospitals etc.
50
55 Max. for shower operation
60 Factory setting
No jumper Limited to 43°C
Install the anti-scalding protection setting jumper in the re-
quired position (= temperature in °C) on the pin strip.