15
2. Operation Instruction for the user and the qualied installer
2.7 Technical Data
Type
DHC
6 EL
DHC
6 EC
DHC
8 EL
DHC
8 EC
DHC
10 EL
Nominal capacity l 0.45 0.50
Design Close outlet
Min. inlet water pressure MPa(bar) 0.02 (0.2)
Max. inlet water pressure MPa(bar) 1.0(10)
Water connection G ½“ (External Thread)
Dimension (W x H x D) mm 200 x 360 x 110
Weight kg 2.0
Electrical connection 1/N/PE/AC 220..240 V
Recommended circuit breaker A 32 40 50
Recommended cable size Sqmm 4-6 6-8 8-10
Rated power (kW) Rated current (A)
220 V
230 V
240 V
Kw - A
6.0 - 27.3
6.6 - 28.7
7.1 - 29.6
kW - A
8.0 - 36.4
8.7 - 37.8
9.5 - 39.6
kW - A
9.9
Safety device - ELCB - ELCB -
Note:
The cable sizes can only be a guiding value. Always abide by the corresponding
local standards, laws and regulations.
Stiebel Eltron cannot be held liable for any damages.