Operation Instruction for the user and the qualied installer
3. Technical Data
Type DHC 8 EL
Norminal capacity l. 0.45
Design Close outlet
Max. water pressure 1000 kPa
Min. water pressure to activate unit 200 kPa
Water connection G ½“ (External Thread) (15mm)
Dimension (W x H x D) mm. 360 x 200 x 110
Weight kg. 2.0
Electrical connection 1/N/PE/AC 220..240 V.
Rated power (kW) Rated current (A.) kW - A
220 V 8.0 - 36.4
230 V 8.7 - 37.8
240 V 9.5 - 39.6
Safety device -
4. Regulations and Provisions
- Regulations of the local power
supply company should be
observed.
- Regulations of the water supply
company should be observed
- Read & study the technical data.
- Install the unit vertically on the
wall.
- Electrical connection to be
secured.
The device must be capable of
being isolated from the mains,
for example by fuses, with an isolating
distance of at least 3.5 mm. in all poles.
5. Important notes
- Make sure the data on the unit rating
plate is current
- Install the unit so that it is ush with
the wall
- Material for the water installation:
Steel, copper, or plastic piping
systems. If plastic piping systems are
being used, the following instructions
are to be respected.
- Temperature : max 60 ˚C
- Pressure : 1000 kPa
The unit must be connected to
the protective earth conductor
(see electric circuit diagram).
Installation must comply with
AS/NZS 3500.4