INSTALLATION
Specication
100 | DHE www.stiebel-eltron.com
17.3 DHW output
The DHW output is subject to the connected power supply, the
appliance's connected load and the cold water inlet temperature.
The rated voltage and rated output can be found on the type plate.
Connected load in kW 38°C DHW output in l/min.
Rated voltage Cold water inlet temperature
380V 400V 415V 5°C 10°C 15°C 20°C
DHE 18/21/24
16.2 7.0 8.3 10.1 12.9
19.0 8.2 9.7 11.8 15.1
21.7 9.4 11.1 13.5 17.2
18.0 7.8 9.2 11.2 14.3
21.0 9.1 10.7 13.0 16.7
24.0 10.4 12.2 14.9 19.0
19.4 8.4 9.9 12.0 15.4
22.6 9.8 11.5 14.0 17.9
25.8 11.2 13.2 16.0 20.5
DHE 27
24.4 10.6 12.4 15.2 19.4
27.0 11.7 13.8 16.8 21.4
Connected load in kW 50°C DHW output in l/min.
Rated voltage Cold water inlet temperature
380V 400V 415V 5°C 10°C 15°C 20°C
DHE 18/21/24
16.2 5.1 5.8 6.6 7.7
19.0 6.0 6.8 7.8 9.0
21.7 6.9 7.8 8.9 10.3
18.0 5.7 6.4 7.3 8.6
21.0 6.7 7.5 8.6 10.0
24.0 7.6 8.6 9.8 11.4
19.4 6.2 6.9 7.9 9.2
22.6 7.2 8.1 9.2 10.8
25.8 8.2 9.2 10.5 12.3
DHE 27
24.4 7.7 8.7 10.0 11.6
27.0 8.6 9.6 11.0 12.9
17.4 Application areas/ conversion table
Electrical resistivity and electrical conductivity
Standard specifica-
tion at 15°C
20°C
25°C
Resis-
tivity
ρ≥
Conductivity σ≤
Resis-
tivity
ρ≥
Conductivity σ≤
Resis-
tivity
ρ≥
Conductivity σ≤
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
900 111 1111 800 125 1250 735 136 1361