www.stiebel-eltron.com DHF C-AU| 9
INSTALLATION
Installation
Fitting the sealing elements for the appliance cover
3
2
D0000043191
1
1 Openings
2 Cover guides
3 Lower fixing screw
!
Material losses
If you cut open the wrong knock-out in the appliance
cover by mistake, you must use a new appliance cover.
Secure the back panel with an additional screw at the
bottom.
Secure the connecting pipes of the tap/valve to the appliance.
Cleanly cut out the openings in the appliance cover. If neces-
sary, use a file.
Click the cover guides into place in the pipe apertures.
10.2 Alternative installation methods
10.2.1 Water installation on unfinished walls
26�02�02�0798
Seal and screw in the twin connectors (not included in stand-
ard delivery).
D0000041724
2
3
1
3
1 Tee for cold water
2 Tee for domestic hot water
3 Cover
Fit the water connections.
D0000043190
Fit the strainer and the plastic profile washer in the tee for
the cold water inlet.
!
Damage to the appliance and environment
The strainer must be fitted for the appliance to function.
When replacing the appliance, check that the strain-
er is present.
Screw the connection pipes from the appliance to the tee.
10.2.2 Power cable for finished walls
!
Material losses
If you cut open the wrong knock-out in the appliance
cover by mistake, you must use a new appliance cover.
Cleanly cut or break out the required opening in the appli-
ance cover (for positions, see chapter "Specification/ Dimen-
sions and connections"). If necessary, use a file.
Route the power cable through the cable grommet and con-
nect it to the mains terminal.
10.3 Completing the installation
Open the shut-off valve in the cold water inlet line.