INSTALLATION
ZĤ¼êÐ|ŒêĒĉ
18 | DHX 15 Select www.stiebel-eltron-usa.com
17. Specification
17.1 Dimensions and connections
c06 c01
c01
c06
b01
7
15
/
16
Ý (202)
1
3
/
8
Ý (35)
4
5
/
16
Ý(109)
1
9
/
16
Ý (40)
3
7
/
8
Ý (98)
14
3
/
16
Ý (360)
Mounting holes, rear cover
12
5
/
8
Ý (320)
½Ý (13)
3
15
/
16
Ý (100)
D0000094547-b
DHX
b02 Entry electrical cables I Finished walls
c01 Cold water inlet Male thread ½˝ NPT
c06 DHW outlet Male thread ½˝ NPT
17.2 Wiring diagram
DHX 15 Select
L L
2/GND ~ 208 / 240V
L N
1/N/GND ~ 208 / 240V
N
L
L
L
D0000077991
1
3
4
2
1 Power PCB with integral safety switch
2 Direct Coil
™
heating system
3 Self-resetting high limit safety cut-out, Klixon
4 Wiring block
17.3 Hot water output
The domestic hot water (DHW) output is subject to the connected
power supply, and the cold water inlet temperature. The rated volt-
age and rated output can be found on the type plate.
Power output in kW 100°F DHW output in gpm
Rated voltage Cold water inlet temperature
Model ŝƃÄŨp ŝÔƃŨp 41°F 50°F 59°F 68°F
DHX 15
Select
10.8 1.24 1.46 1.78 2.28
14.4 1.67 1.97 2.4 3.07
Power output in kW 122°F DHW output in gpm
Rated voltage Cold water inlet temperature
Model ŝƃÄŨp ŝÔƃŨp 41°F 50°F 59°F 68°F
DHX 15
Select
10.8 0.9 1.02 1.16 1.35
14.4 1.21 1.37 1.56 1.82
Power output in kW 38°C DHW output in l/min
Rated voltage Cold water inlet temperature
Model ŝƃÄŨp ŝÔƃŨp 5°C 10°C 15°C 20°C
DHX 15
Select
10.8 4.6 5.5 6.6 8.5
14.4 6.2 7.3 8.9 11.4
Power output in kW 50 °C DHW output in l/min
Rated voltage Cold water inlet temperature
Model ŝƃÄŨp ŝÔƃŨp 5°C 10°C 15°C 20°C
DHX 15
Select
10.8 3.4 3.8 4.4 5.1
14.4 4.6 5.1 5.9 6.9