EasyManua.ls Logo

STIEBEL ELTRON SH 30 S - Details on Energy Consumption; Fault Conditions; Heat-Up Diagram

STIEBEL ELTRON SH 30 S
76 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 | SH S www.stiebel-eltron.com
INSTALLATION
Specication
16.3 Heat-up diagram
The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Diagram with 15°C cold water temperature:
Set temperature setting 82°C
10080 15030
2
4
6
2
4
5
8
10
12
14
50 120
1
3
84�02�02�0041�
X Nominal capacity [I]
Y Duration [h]
1 1kW
2 2kW
3 3kW
4 4kW
5 6kW
16.4 Fault conditions
In the event of a fault, temperatures of up to 95°C at 0.6MPa
can occur.
16.5 Details on energy consumption
Product data complies with EU regulations relating to the Directive
on the ecodesign of energy related products (ErP).
SH 30 S SH 50 S SH 80 S SH 100 S SH 120 S SH 150 S
073047 073048 073049 073050 073051 073052
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile S M M L L XL
Energy efficiency category B C C C C C
Energy conversion efficiency % 36 38 37 38 39 39
Daily power consumption kWh 2.437 6.233 6.419 12.288 12.256 19.859
Annual power consumption kWh 518 1349 1381 2666 2661 4321
Default temperature setting °C 60 60 60 60 60 60
Sound power level dB(A) 15 15 15 15 15 15
Off-peak periods possible No No No No No No