30 | SHW S www.stiebel-eltron.com
INSTALLATION
Specication
Dual circuit operation, dual meter measurement with power
supply utility contact
1/N/PE ~ 230 V
3/N/PE ~ 400 V
5
PE
K1K2
K2K1
L1
N
L3
L2
26�02�79�0069
3
2
1
4
K1 Contactor 1
K2 Contactor 2
1 Connections also required for 3/N/PE ~ 400V
2 Power supply utility contact
3 Off-peak tariff meter
4 Peak tariff meter
Ensure connection to the same phase.
16.3 Details on energy consumption
Product datasheet: Conventional water heaters to regulation (EU) no. 814/2013
SHW 200 S SHW 300 S SHW 400 S
182120 182121 182122
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile XL XL XL
Energy efficiency class C C C
Energy conversion efficiency % 39 39 39
Annual power consumption kWh 4294 4311 4268
Default temperature setting °C 60 60 60
Sound power level dB(A) 15 15 15
Option for exclusive operation during off-peak periods - - -
Special information on measuring efficiency
Smart function - - -
Cylinder capacity l 200 300 400
Mixed water volume at 40 °C l 392 582 768
Daily power consumption kWh 19.699 19.796 19.544
16.4 Heat-up diagram
The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
At 10°C cold water temperature and temperature setting "E":
400300
2
4
6
8
10
12
2
3
4
1
84�02�02�0016
X Nominal capacity [I]
Y Duration [h]
1 2kW
2 3kW
3 4kW
4 6kW
16.5 Fault conditions
In the event of a fault, temperatures of up to 95°C at 0.6MPa
can occur.

Table of Contents