OPERATION
Settings
ENGLISH
www.stiebel-eltron.com VRC-W 400 (E) | 7
Direct selection parameters
VRC-W 400 VRC-W 400 E
Description Code
level
Unit Min. Max. Options Stand-
ard
Min. Max. Options Stand-
ard
P1 Set room temperature A0 °C 5 28 20 5 28 20
P2 Intens. vent. time A0 min. 1 240 30 1 240 30
P3
Operating mode heat recovery
bypass
A0
Disabled (0)|
Bypass/window contact (1)|
Outdoor air routing automatic(2)|
Extract air routing autom. (3)
(2)
Disabled (0)|
Bypass/window contact (1)|
Outdoor air routing automatic(2)|
Extract air routing autom. (3)
(2)
P4 Filter reset A0 Off | On Off Off | On Off
P28 Enable fan A0 Off | On Off Off | On Off
P35
Cooling/heating, heat recovery
bypass
A0
Cooling/heating (1)|
Cooling (2)|
Heating (3)
(1)
Cooling/heating (1)|
Cooling (2)|
Heating (3)
(1)
P80 Day A0
P81 Time A0 00:00 23:59 00:00 23:59
4.4 Menus
Note
Some parameters are protected by a code and can only
be set by a qualified contractor or the service department.
Depending on the set code, not all parameters may be
displayed in the individual menus.
f Press the "MENU" button to access the menus from the home
screen.
Menu Description
Info Information about the actual values of the unit
Diagnostics Fault messages, operating time, maintenance intervals
Programs Fan program
Settings Adjustable values and functions
4.4.1 "Info" menu
Info
Value
 Bypass status Off | On
 Extract air temp. °C
 Extract air hum. %
4.4.2 "Diagnostics" menu
Diagnostics
Value
 Notification list Off | On
 Filter runtime h
 Filter reset Off | On
Diagnostics
 Notification list
The faults most recently registered by the unit are stored in the
notification list. The most recent fault is stored in #1, the oldest
error in #10.
If no faults are entered, dashes are shown. Possible faults are
listed for qualified contractors in the "Troubleshooting" chapter.
 Filter runtime
The filter runtime is dependent on the operating conditions and
has been defined by the qualified contractor.
 Filter reset
f After changing the filters, set the "Filter reset" to "On".
The unit resets the filter runtime to 0 and the "Filter reset" is au-
tomatically reassigned the value "Off". The filter change warning
signal goes out.