OPERATION
Settings
10 | VRC-W 400 (E) www.stiebel-eltron.com
 Operating mode heat recovery bypass
Effect
Disabled Bypass mode is permanently disabled. Air flows
through the heat exchanger.
Bypass/window contact
Bypass mode is active. The air flow bypasses the
heat exchanger. The "Bypass mode" symbol appears
on the display.
Outdoor air routing au-
tomatic
Bypass mode operates with summer day detection.
This option is set in the delivered condition. The
"Bypass mode" symbol appears on the display.
Extract air routing
autom.
Bypass mode operates subject to the extract air
temperature. The "Bypass mode" symbol appears
on the display.
Note
The qualified contractor can set the parameters men-
tioned in the description of this parameter.
- Temperature to enable heat recovery bypass
- Temperature to block heat recovery bypass
- Hysteresis for heat recovery bypass
- Temp. differential for heat recovery bypass
 Outdoor air routing automatic: Bypass mode with
summer day detection
For bypass mode to be enabled, the following condition must be
met for 60minutes:
- Set room temperature+ Temp. differential for heat recovery
bypass< Outdoor air temp.
If all the following conditions are met, the appliance switches to
bypass mode.
- Extract air temp.- Hysteresis for heat recovery bypass> Out-
door air temp.
- Extract air temp.> Set room temperature
If one of the following conditions is met, the appliance terminates
bypass mode.
- Outdoor air temp.< Temperature to block heat recovery
bypass
- Extract air temp.- Hysteresis for heat recovery bypass< Out-
door air temp.
- Extract air temp.< Set room temperature
 Extract air routing autom.: Bypass mode subject to
extract air temperature
For bypass mode to be enabled, the following condition must be
met for 60minutes:
- Set room temperature+ Temp. differential for heat recovery
bypass< Extract air temp.
This delayed enabling prevents cooling down in spring and au-
tumn.
If all the following conditions are met, the appliance switches to
bypass mode.
- Extract air temp.- Hysteresis for heat recovery bypass> Out-
door air temp.
- Extract air temp.> Set room temperature
If one of the following conditions is met, the appliance terminates
bypass mode.
- Outdoor air temp.< Temperature to block heat recovery
bypass
- Extract air temp.- Hysteresis for heat recovery bypass< Out-
door air temp.
- Extract air temp.< Set room temperature
 Cooling/heating, heat recovery bypass
f Set the bypass mode control according to the temperature.
Parameter Effect
Cooling/heating Depending on the temperature, use the outdoor air for cool-
ing or heating.
Cooling Summertime: Use cool outdoor air.
Heating Spring and autumn: Use warm outdoor air.
 Enable fan
You can switch off the fans at any time via the programming unit
menu, e.g. to deactivate ventilation if there is a fire.
Effect
Off The fans are disabled. The "Fan disable" symbol appears on the display.
On The fans are enabled.
4.5 Switching off the appliance
D0000040280
The appliance has no ON/OFF switch. Disconnect the power supply
by pulling the power plug from its socket.