Special information
www.stiebel-eltron.com WPF | 3
SPECIAL INFORMATION
- The appliance may be used by children aged8
and up and persons with reduced physical, sen-
sory or mental capabilities or a lack of experience
and know-how, provided that they are supervised
or they have been instructed on how to use the
appliance safely and have understood the result-
ing risks. Children must never play with the ap-
pliance. Children must never clean the appliance
or perform user maintenance unless they are
supervised.
- Use a permanent connection to the power supply.
Ensure the appliance can be separated from the
power supply by an isolator that disconnects all
poles with at least 3mm contact separation.
- Maintain the minimum clearances to ensure trou-
ble-free operation of the appliance and facilitate
maintenance work.
- In dual mode operation, return water from the
second heat generator may flow through the heat
pump. Please note that the return water tempera-
ture may be a maximum of 60°C.
- Cooling mode is only possible in conjunction with
the WPAC 1 cooling module. Set parameter COOL-
ING to ACTIVE COOLING. The COOLING parameter
will only be shown if a FEK or FE 7 remote control
is connected. Cooling mode is only possible in
summer mode.
- The air outlet in the knurled cap of the quick-ac-
tion air vent valve must not point towards the
MFG PCB. Close the quick-action air vent valve
again after venting.
- Maintenance work, such as checking the electri-
cal safety, must only be carried out by a qualified
contractor.
- We recommend an annual inspection (to establish
the system's current condition), and maintenance
by a qualified contractor if required (to return the
system to the desired condition).
- Never interrupt the power supply, even outside
the heating period. The system's active frost pro-
tection is not guaranteed if the power supply is
interrupted.
- There is no need to shut the system down in
summer. The heat pump manager has an auto-
matic summer/winter changeover.
DHW cylinders
- Regularly activate the safety valve to prevent
it from becoming blocked e.g. by limescale
deposits.
- Drain the DHW cylinder as described in the chap-
ter "Installation/ Maintenance/ Draining the
DHW cylinder".
- Install a type-tested safety valve in the cold water
supply line. For this bear in mind that, depending
on the static pressure, you may also need a pres-
sure reducing valve.
- The safety valve discharge aperture must remain
open to the atmosphere.
- Install the safety valve discharge pipe with a con-
stant fall to the discharge outlet.
- Size the discharge outlet so that water can drain
off unimpeded when the safety valve is fully
opened.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON WPC 07 cool and is the answer not in the manual?

STIEBEL ELTRON WPC 07 cool Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelWPC 07 cool
CategoryHeat Pump
LanguageEnglish

Related product manuals