13.4 WPM3i commissioning report
The following lists the parameters that can be adjusted via the programming unit.
Programs / heat-up program Setting range Standard System value
LOW END TEMPERATURE 20..40 °C 25.0°C
TEMP. RISE PERIOD 0 to 5 days 2 days
MAXIMUM TEMPERATURE 20...50°C, inc 0.5K 40.0°C
MAX TEMPERATURE DURATION 0 to 10 days 0 days
RISE PER DAY 1 to 10 K/day 1 K/day
Settings / general Setting range Standard System value
CONTRAST 01 to 10 5
BRIGHTNESS 0 to 100 % 50 %
TOUCH SENSITIVITY 01 to 10 04
TOUCH ACCELERATION 02 to 10 06
Settings / heating / heating circuit 1 Setting range Standard System value
SET ROOM TEMP COMFORT 5 to 30 °C 20°C
SET ROOM TEMP ECO 5 to 30 °C 20°C
HEATING CURVE RISE 0.2 to 3 0.6
Settings / heating / heating circuit 2 Setting range Standard System value
SET ROOM TEMP COMFORT 5 to 30 °C 20°C
SET ROOM TEMP ECO 5 to 30 °C 20°C
HEATING CURVE RISE 0.2 to 3 0.2
Settings / heating / standard setting Setting range Standard System value
BUFFER OPERAT ON / OFF OFF
SUMMER MODE ON / OFF ON
OUTSIDE TEMPERATURE 3 to 30 °C 20°C
BUILDING HEAT BUFFER 1 to 3 1
MAXIMUM RETURN TEMP 20 to 55°C 55°C
MAXIMUM FLOW TEMP 20 to 65°C 60 °C
MIXER DYNAMICS 30 to 240 100
MAXIMUM MIXER TEMPERATURE 20 to 90°C 50 °C
FIXED VALUE OPERATION OFF / 20 ..50 °C OFF
OPTIMUM HEATING CURVE OFF / 0.01 ..0.1 OFF
FROST PROTECT -10 to 10°C 4°C
Settings / heating / FE7 remote control Setting range Standard System value
HEATING CIRC PRESELECTION 1 / 2 heating circuits Heating circuit 1
ROOM INFLUENCE OFF / 0 to 20 5
ROOM CORRECTION -5 to 5 K 0
Settings / heating / pump cycles Setting range Standard System value
PUMPCYCLES ON / OFF OFF
Settings / heating / electric reheating Setting range Standard System value
DUAL MODE TEMP HEATING -40 to 40°C -20°C
LOWER APP LIMIT HEATING OFF / -39.5 to 40°C -20°C
Settings / DHW / DHW temperatures Setting range Standard System value
SET DHW TEMP COMFORT 10 to 60°C 50 °C
SET DHW TEMP ECO 10 to 60°C 50 °C
Settings / DHW / standard setting Setting range Standard System value
DHW HYSTERESIS 1 to 10K 5K
DHW LEARNING FUNCTION ON / OFF OFF
DHW CORRECTION 0 to 5 °C 3°C
COMBI CYLINDER ON / OFF OFF
PASTEURISATION ON / OFF OFF
Settings / DHW / electric reheating Setting range Standard System value
DUAL MODE TEMP DHW -40 to 40°C -20°C
LOWER APP LIMIT DHW OFF / -39.5 to 40°C -20°C

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON WPC 07 cool and is the answer not in the manual?

STIEBEL ELTRON WPC 07 cool Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelWPC 07 cool
CategoryHeat Pump
LanguageEnglish

Related product manuals