INSTALLATION
Electrical connection
www.stiebel-eltron.com WPE-I H(K) 230 Premium | 15
10.2.1 Compressor and electric emergency/booster heater
Note
The appliance can be operated in single-phase or three-
phase mode.
Appliance
function
Effect of the electric emergency/booster heater
Mono energet-
ic operation
If the dual mode point is undershot, the electric emergency/
booster heater safeguards both the heating operation and the
provision of high DHW temperatures.
Emergency
mode
If the heat pump shuts down due to a fault, the heating output
is covered by the electric emergency/booster heater.
Connect cables according to the following diagram.
D0000076876
Single-phase operation
XD1 Compressor (inverter)
L, N, PE
XD1 Electric emergency/booster heater (DHC)
L', L", N', N", PE
XD3 Control voltage
L, N, PE
Alternatively: Three-phase operation
Note
Connect the N, N', and N” connections with a jump-
er.
XD1 Compressor (inverter)
Electric emergency/booster heater (DHC)
L1, L2, L3, N, PE
XD3 Control voltage
L, N, PE
Route cables and leads through the strain relief fittings.
Check that the strain relief fittings are working as intended.
If no voltage is applied to the power supply utility enable signal,
the heat pump will not start.
If no ripple control receiver is fitted, install a jumper be-
tween EVU1 and EVU2.
10.2.2 Heat pump manager terminal assignment
X2.2 X2.3 X2.4 X2.5 X2.6 X2.7 X2.8 X2.9 X2.10 X2.11 X2.12 X2.13 X2.14 X2.15
X1.1
CAN A
X1.19
CAN A
X1.18
CAN B
X1.17X1.16X1.15X1.14X1.13X1.12X1.2
CAN B
X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.9 X1.10 X1.11
X2.1
D0000071841
Safety extra low voltage
X1.1
CAN A
+
-
L
H
+
-
L
H
CAN (connection for heat pump and WPE heat
pump extension)
X1.2
CAN B
+
-
L
H
+
-
L
H
CAN (connection for FET remote control and
ISG Internet Service Gateway)
X1.3 Signal
Earth
1
2
Outside sensor
X1.4 Signal
Earth
1
2
Buffer sensor (heating circuit sensor 1)
X1.5 Signal
Earth
1
2
Flow sensor
X1.6 Signal
Earth
1
2
Heating circuit sensor 2
X1.7 Signal
Earth
1
2
Heating circuit sensor 3
X1.8 Signal
Earth
1
2
DHW cylinder sensor
X1.9 Signal
Earth
1
2
Source sensor
X1.10 Signal
Earth
1
2
2nd heat generator (2.WE)
X1.11 Signal
Earth
1
2
Cooling flow
X1.12 Signal
Earth
1
2
DHW circulation sensor
X1.13
Signal
Earth
Signal
1
2
3
FE7 remote control/ telephone remote
switch/ heating curve optimisation/ SGReady
X1.14
Constant 12V
Input
GND
+
IN
Analogue input 0-10V
X1.15
Constant 12V
Input
GND
+
IN
Analogue input 0-10V
X1.16 Signal
Earth
1
2
PWM output 1
X1.17 Signal
Earth
1
2
PWM output 2
X1.18
CAN B
+
-
L
H
+
-
L
H
CAN (connection for FET remote control and
ISG Internet Service Gateway)
X1.19
CAN A
+
-
L
H
+
-
L
H
CAN (connection for heat pump and WPE heat
pump extension)