INSTALLATION
Specication
42 | WPE-I H(K) 230 Premium www.stiebel-eltron.com
16.4 Data table
WPE-IH230Premium
Output details apply to new appliances with clean heat exchangers.
The power consumption figures for the integral auxiliary drives are maximum values and may vary subject to operating point.
The power consumption of the integral auxiliary drives is included in the output details of the heat pump (to EN14511).
WPE-I 04 H 230
Premium
WPE-I 06 H 230
Premium
WPE-I 08 H 230
Premium
WPE-I 12 H 230
Premium
WPE-I 15 H 230
Premium
202613 238610 238611 238612 238613
Heating output
Heating output at B0/W35 (min./max.) kW 1.04 - 4.19 1.04 - 6.57 1.04 - 7.64 2.14 - 12.66 2.14 - 14.78
Heating output at B0/W35 (EN 14511) kW 1.96 2.37 2.78 4.19 5.18
Heating output at B0/W55 (EN 14511) kW 1.28 2.01 2.42 4.2 4.72
Power consumption
Power consumption at B0/W35 (EN 14511) kW 0.43 0.52 0.6 0.84 1.07
Power consumption at B0/W55 (EN 14511) kW 0.47 0.69 0.79 1.34 1.48
Power consumption, emergency/booster heater kW 5.8 5.8 5.8 5.8 5.8
Max. power consumption, circulation pump on the
heating side
W 45 45 45 76 76
Max. power consumption, circulation pump on the
source side
W 140 140 140 140 140
Coefficients of performance
SCOP (EN 14825) 5.07 5.20 5.12 5.59 5.44
Coefficient of performance at B0/W35 (EN 14511) 4.60 4.60 4.67 5.01 4.86
Coefficient of performance at B0/W55 (EN 14511) 2.73 2.91 3.07 3.13 3.18
Sound emissions
Sound power level (EN 12102) dB(A) 38 - 40 38 - 43 39 - 45 39 - 46 39 - 47
Application limits
Max. permissible pressure MPa 0.3 0.3 0.3 0.3 0.3
Min. application limit on the heating side °C 15 15 15 15 15
Max. application limit on the heating side °C 75 75 75 75 75
Min. application limit, heat source °C -5 -5 -5 -5 -5
Max. application limit, heat source °C 20 20 20 20 20
Shutdown pressure, brine pressure switch (positive
pressure)
MPa 0.7 0.7 0.7 0.7 0.7
Energy data
Energy efficiency class A+++/A+++ A+++/A+++ A+++/A+++ A+++/A+++ A+++/A+++
Electrical data
Starting current (with/without starting current limiter) A <25 <25 <25 <25 <25
Emergency/booster heater fuse protection A 2 x B 16 2 x B 16 2 x B 16 2 x B 16 2 x B 16
Control unit fuse protection A 1 x B 16 1 x B 16 1 x B 16 1 x B 16 1 x B 16
Compressor fuse protection A 1 x B 16 1 x B 16 1 x B 16 1 x B 25 1 x B 25
Rated voltage, emergency/booster heater V 230 230 230 230 230
Rated voltage, control unit V 230 230 230 230 230
Rated voltage, compressor V 230 230 230 230 230
Frequency Hz 50 50 50 50 50
Emergency/booster heater phases 2/N/PE 2/N/PE 2/N/PE 2/N/PE 2/N/PE
Control unit phases 1/N/PE 1/N/PE 1/N/PE 1/N/PE 1/N/PE
Compressor phases 1/N/PE 1/N/PE 1/N/PE 1/N/PE 1/N/PE
Max. operating current A 8.4 13 15.09 24.32 24.48
Versions
Refrigerant R454C R454C R454C R454C R454C
Refrigerant charge kg 2.2 2.2 2.2 3.1 3.1
Global warming potential of the refrigerant (GWP100) 148 148 148 148 148
CO
2
equivalent (CO
2
e) t 0.32 0.32 0.32 0.45 0.45
Condenser material 1.4401/Cu 1.4401/Cu 1.4401/Cu 1.4401/Cu 1.4401/Cu
Evaporator material 1.4401/Cu 1.4401/Cu 1.4401/Cu 1.4401/Cu 1.4401/Cu
Circulation pump type on the heating side Yonos PARA 25/7.0 Yonos PARA 25/7.0 Yonos PARA 25/7.0 Yonos PARA 25/7.5 Yonos PARA 25/7.5
Circulation pump type, source side Grundfos UPML Grundfos UPML Grundfos UPML Grundfos UPML Grundfos UPML
IP rating IP20 IP20 IP20 IP20 IP20