OpEraTiON
Settings
10 | WWK222-302 H www.stiebel-eltron.com
4.4 Adjusting the settings
The default display shows the mixed water volume.
The "Menu" button allows you to call up
all information and adjustment options in
sequence. The relevant symbol appears.
Menu
Mixed water volume display
Actual temperature display
Set temperature 1
Set temperature 2
Fan speed
Air intake temperature display
Enable the “Runtime-dependent rapid
heat-up” function
In appliances with no electric
emergency/booster heater,
this parameter has no func-
tion.
Time set for the “Runtime-dependent
rapid heat-up” function
In appliances with no electric
emergency/booster heater,
this parameter has no func-
tion.
Change units
Charge level
Fault code
E fault code
Advanced menu (with service plug only)
Integral sensor offset
Set the cylinder volume
Compressor lockout due to evaporator
fault
Clear high pressure lockout
Clear low pressure lockout
Temperature of evaporator fins
Number of times hot gas temperature
sensor was triggered
Number of defrost faults
Number of low pressure triggers
Number of high pressure triggers
Hot gas temperature switching value
Fan lead time
Integral sensor replacement
Set value limit
Menu
Mixed water volume display
The currently available mixed water
volume at 40°C and at 15°C cold water
temperature is shown.
"--L" is shown if less than 10l mixed
water is currently available.
DHW demand for Mixed water volume at 40°C
Bath 120-150 l
Shower 30-50l
Washing hands 2-5l
The mixed water volume that can be achieved depends on the
cylinder size and the set temperature selected.
Actual temperature display
In the "Mixed water volume" menu, press
"Menu" once to access the "Actual tem-
perature" menu.
The "Actual temperature" symbol ap-
pears.
The current actual temperature is shown.
The actual temperature is the tempera-
ture in the upper section of the DHW cyl-
inder, and therefore largely corresponds
to the outlet temperature.
Set temperature1
Note
For hygiene and other reasons, only change this value if
instructed by Stiebel Eltron representative..
Set temperature1 is the DHW temperature to which the appliance
regulates if no external signal transmitter is connected and active.
Factory setting
Set temperature 1 °C 1
In the "Actual temperature" menu, press
"Menu" once to access the "Set temper-
ature1" menu.
The set temperature1 symbol appears.
You can change the value using the "Plus"
and "Minus" buttons. Setting range: 61
- 65 °C