iNSTallaTiON
Specication
www.stiebel-eltron.com WWK222-302 H | 39
WWK 222 WWK 222 H WWK 302 WWK 302 H
Connections
Condensate connection G 3/4 G 3/4 G 3/4 G 3/4
Safety valve connection Rp 3/4 Rp 3/4 Rp 3/4 Rp 3/4
Water connection G 1 (with adaptor
Rp 3/4 fem.)
G 1 (with adaptor
Rp 3/4 fem.)
G 1 (with adaptor
Rp 3/4 fem.)
G 1 (with adaptor
Rp 3/4 fem.)
The output data refers to new appliances with clean heat ex-
changers.
Nominal data to EN16147 – heat pump for recirculation air
Further details
WWK 222 WWK 222 H WWK 302 WWK 302 H
231209 233209 231211 232905
Maximum altitude for
installation
m 2000 2000 2000 2000
16.5 Appliance parameters
WWK 222 WWK 222 H WWK 302 WWK 302 H
Reduced start hysteresis K 6 6 6 6
Maximum temperature increase time h 13 13 13 13
Maximum defrost time min 180 180 180 180
Defrost end temperature °C 5 5 5 5
Minimum evaporator temperature °C -20 -20 -20 -20
Recurring pressure fault - 5 5 5 5
Pressure fault evaluation time h 5 5 5 5
Compressor lockout time min 20 20 20 20
Set rapid heat-up temperature °C 65 65 65 65
Start temperature for the frost protection function °C 8 8 8 8
Set temperature 1 ( Factory setting ) °C 61 61 61 61
16.6 Standardised output data
Information on determining and interpreting the specified stand-
ardised output data
Standard: EN 16147
The output data specifically mentioned in text, diagrams and
technical datasheets has been determined in line with the test
conditions described in the standard shown in the heading of
this chapter.
Generally, these standardised test conditions will not fully meet
the conditions found at the installation site of the system user.
Depending on the chosen test method and the extent to which
the selected method deviates from the conditions described in
the standard shown in the heading of this chapter, any deviations
can have a considerable impact. Additional factors that have an
influence on the test values are the measuring equipment, the
system configuration, the age of the system and the flow rates.
A confirmation of the specified output data can only be obtained
if the conditions applicable to the relevant test match those of the
standard shown in the heading of this chapter.