Loading...
INSTALLATION
Specication
www.stiebel-eltron.com WWK 223-303 electronic | 35
ENGLISH
Further details
WWK 223 electronic WWK 303 electronic
234406 234405
Maximum altitude for installation m 2000 2000
16.5 Appliance parameters
WWK 223 electronic WWK 303 electronic
Reduced start hysteresis K 6 6
Maximum temperature increase time h 13 13
Maximum defrost time min 180 180
Defrost end temperature °C 5 5
Set setback value °C 52 52
minimum evaporator temperature °C -20 -20
Recurring pressure fault - 5 5
Pressure fault evaluation time h 5 5
Compressor lockout time min 20 20
Set rapid heating temperature °C 65 65
Start temperature for the frost protection function °C 8 8
Set temperature 1 ( Factory setting ) °C 62 62
Time set for the "runtime-dependent rapid heat-up" function ( Factory setting ) °C 10 10