EasyManua.ls Logo

STIEBEL ELTRON WWK 223 electronic - Electrical Connection

STIEBEL ELTRON WWK 223 electronic
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Installation
www.stiebel-eltron.com WWK 223-303 electronic | 21
ENGLISH
10.3 Electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with national and regional regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3mm contact separation.
This requirement can be met by contactors, isolators,
fuses, etc.
WARNING Electrocution
Observe the safety measures to prevent contact with
dangerous 'live' currents.
WARNING Electrocution
Coming into contact with 'live' components presents a
threat to life. Disconnect the appliance from the power
supply before carrying out work on the control panel.
Prevent the power supply from being switched on while
you are working on the system.
WARNING Electrocution
Insufficient earthing can lead to electrocution. Ensure
the appliance is earthed according to locally applicable
requirements.
WARNING Electrocution
The power cable must only be replaced (for example if
damaged) by a qualified contractor authorised by the
manufacturer (connection typeX).
!
Material losses
Install a residual current device (RCD).
!
Material losses
The specified voltage must match the mains voltage. Ob-
serve the type plate.
!
Material losses
Never connect the appliance to the power supply before
the DHW cylinder is filled.
The appliance is supplied with a flexible power cable without plug.
f If the power cable is not long enough, unclamp it from the
appliance. Use a suitable installation cable.
f Route the new power cable through the cable entry.
f Connect the connecting cable properly inside the appliance.
10.3.1 Standard connection without external signal transmitter
X0
2
L
L
N
N
PE
PE
1
1
2
X3
2
3
3
1
1
2
L
N
PE
GNYE
BU
BN
D0000050560
BN Brown
BU Blue
GNYE Green/yellow
10.3.2 Connection options: Operation with external switching
device that interrupts appliance power supply
To ensure cylinder corrosion protection, appliances are equipped
with a maintenance-free impressed current anode as standard. A
maintenance-free impressed current anode, when compared to a
sacrificial anode, offers the greatest protection and saves on costs
for maintenance that would otherwise be required. To ensure cyl-
inder corrosion protection however, the impressed current anode
must be supplied with power permanently.
If the device is to be used with external switching devices (e.g.
external time switch, switched socket, energy management sys-
tem, power-interrupting signal from the power supply utility)
that interrupt the appliance power supply, the impressed current
anode must not be subject to the effects of such devices, but sup-
plied independently. For such cases, the appliance allows separate
power supplies for load (compressor) and electronic (including
impressed current anode) circuits.
f Remove the appliance cover (see chapter "Cleaning and
maintenance/ Removing the appliance cover").
D0000056083
1
2
1 Strain relief
2 Terminal X0
f Prepare the electric cables in such a way that they terminate
with wire ferrules.
f Push the cables through one of the cable entries in the appli-
ance casing.
f Route leads through the strain relief.
f Remove the jumper which leads from X0/N to X0/2 in the de-
livered condition.
f Remove the jumper which leads from X0/L to X0/1 in the de-
livered condition.

Table of Contents