Stihl MS 500i W - Clearing the Combustion Chamber

Stihl MS 500i W
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0458-809-0121-A
36
English
18 Troubleshooting
18.2 Clearing the Combustion Chamber
Engage the chain brake.
Rotate the filter cover lock (1) a quarter turn
counterclockwise.
Remove the filter cover (2).
Rotate the shroud lock (1) a quarter turn
counterclockwise.
Remove the shroud (4).
Pull off the spark plug boot (5).
Unscrew the spark plug.
Dry the spark plug.
WARNING
Unconfined sparks may occur if the starter grip is pulled after
the spark plug boot has been removed. Sparks may cause a
fire or an explosion in an easily combustible or explosive
environment. This can result in serious or fatal injuries and
damage to property.
Depress the stop switch and keep it depressed before
pulling the starter grip.
Depress the stop switch and hold it in that position.
Pull the starter grip and guide it back several times.
The combustion chamber is cleared.
Insert and tighten down the spark plug.
Position the spark plug boot (5) so that the lug (6) points
vertically upwards.
Press the spark plug boot (5) firmly home.
Place the shroud (4) in position.
Rotate the shroud lock (3) clockwise until you hear a click.
The shroud lock (3) is secure.
Fit the filter cover (2).
Rotate the filter cover lock (1) clockwise until you hear a
click.
The filter cover lock (1) is secure.
3
0000-GXX-5821-A0
2
5
1
4
0000-GXX-5822-A0
5
6

Table of Contents