19 Specifications
19.2 Pressure washer STIHL RE 170 PLUS
Version 230 V / 50 Hz
Fuse (characteristic "C" or "K"): 16 A
Power consumption: 3.3 kW
Maximum permissible mains impedance: 0.45 Ohm
Electrical protection class: I
Degree of electrical protection: IPX5 (protection from
water jets in any direction)
Working pressure (p): 15 MPa (150 bar)
Max. permissible pressure (p max.): 18 MPa (180 bar)
Max. water supply pressure (p in max.): 1 MPa (10 bar)
Maximum water throughput (Q max): 10.8 l/min (648 l/h)
Minimum water throughput (Q min): 9.5 l/min (570 l/h)
Maximum recoil force: 24 N
Max. suction lift: 0.5 m
Max. water temperature in pressure mode (t in max):
60 °C
Max. water temperature in suction mode: 20 °C
Dimensions
Length: 383 mm
Width: 380 mm
Maximum height: 981 mm
Minimum height: 792 mm
Length of high-pressure hose: 12 m
Weight (m) with accessory attached: 31 kg
Version 220-240 V / 50 Hz
Fuse (characteristic "C" or "K"): 10 A
Power consumption: 2.2 kW
Maximum permissible mains impedance: 0.45 Ohm
Electrical protection class: I
Degree of electrical protection: IPX5 (protection from
water jets in any direction)
Working pressure (p): 12 MPa (120 bar)
Max. permissible pressure (p max.): 18 MPa (180 bar)
Max. water supply pressure (p in max.): 1 MPa (10 bar)
Maximum water throughput (Q max): 8.7 l/min (522 l/h)
Minimum water throughput (Q min): 7.8 l/min (468 l/h)
Maximum recoil force: 16 N
Max. suction lift: 0.5 m
Max. water temperature in pressure mode (t in max):
60 °C
Max. water temperature in suction mode: 20 °C
Dimensions
Length: 383 mm
Width: 380 mm
Maximum height: 981 mm
Minimum height: 792 mm
Length of high-pressure hose: 12 m
Weight (m) with accessory attached: 31 kg
19.3 Extension Cords
If an extension cord is used, the cross sectional area of its
conductors must meet the following minimum requirements
– depending on the line voltage and length of the extension
cord:
220 V to 240 V
Cord length up to 20 m: AWG 15 / 1.5 mm²
Cord length 20 m up to 50 m: AWG 13 / 2.5 mm²
100 V to 127 V
Cord length up to 10 m: AWG 14 / 2.0 mm²
Cord length 10 m up to 30 m: AWG 12 / 3.5 mm²