EasyManuals Logo

Stihl RE 150 User Manual

Stihl RE 150
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
The pressure washer should be stored in such
a way that the following conditions are fulfilled:
The pressure washer is out of the reach of
children.
The pressure washer is clean and dry.
The pressure washer is in an enclosed
room.
The pressure washer is in a temperature
range above 0 °C.
If the pressure washer cannot be protected
from frost in storage: Protect the pressure
washer with antifreeze.
15 Cleaning
15.1 Cleaning the high-pressure
washer and accessories
Switch off the high-pressure washer and pull
the mains plug out of the socket.
Clean the high-pressure washer, high-pres‐
sure hose, spray gun and accessories with a
damp cloth.
Clean the connectors and couplings on the
high-pressure washer, high-pressure hose and
spray gun with a damp cloth.
Clean vents with a paintbrush.
15.2 Cleaning nozzle and spray
lance
0000098883_A1
Rinse the nozzle and spray lance under run‐
ning water and dry with a cloth.
0000-GXX-4370-A0
If the nozzle is clogged: Clean the nozzle with
the cleaning pin.
15.3 Cleaning the water intake
screen
2
1
0000-GXX-9881-A0
Unscrew the connector (1) of the water con‐
nection.
Pull water intake screen (2) out of the water
connection.
Rinse out the water intake screen (2) under
running water.
Insert water intake screen (2) into water con‐
nection.
Attach the connector (1) and tighten it by
hand.
15.4 Cleaning the water filter
The water filter must be disassembled to clean it.
5
1
0000-GXX-4373-A0
2
3
1
4
Remove gasket (1) from the fastener (2).
Unscrew fastener (2) from filter housing (5).
Remove gasket (3) from the fastener (2).
Remove filter (4) from the filter housing (5).
Rinse gaskets (1 and 3), fastener (2) and fil‐
ter (4) under running water.
Grease the gaskets (1 and 3) with grease for
fittings.
Reassemble the water filter.
16 Maintenance
16.1 Maintenance intervals
Maintenance intervals depend on the ambient
conditions and the operating conditions. STIHL
recommends the following maintenance inter‐
vals:
Monthly
Clean water intake screen.
English 15 Cleaning
20 0458-603-0121-B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl RE 150 and is the answer not in the manual?

Stihl RE 150 Specifications

General IconGeneral
Maximum Pressure150 bar
Operating Pressure135 bar
Max. Pressure150 bar
Max. Water Temperature60 °C
Power Cable Length5 m
High-Pressure Hose Length9 m