13
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA for 30 ms.
The power connection must correspond
to IEC 60364-1 and relevant national
regulations.
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances. Trouble is not anticipated at
power line impedances less than
0.15 Ω.
Extension cord
The design of the extension cord must at
least fulfill the same features as the
connecting cord on the machine.
Observe the design marking (type
designation) on the connecting cord.
The cores in the cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off
see "Switching off the machine"
N Plug the power cord or extension
cord into a properly installed outlet
N Turn on water supply
NOTICE
The machine may only be switched on
when the water intake hose is connected
and the water supply has been turned
on. Otherwise the machine may be
damaged due to lack of water.
N Completely unroll the high-pressure
hose
N Move the master switch to I – now
the machine is in standby mode
N Point the spray gun at the object to
be cleaned – never at persons!
Connecting to Power Supply
Cord length Minimum cross-
section
220 V – 240 V:
Up to 20 m 1.5 mm
2
20 m to 50 m 2.5 mm
2
100 V – 127 V:
Up to 10 m AWG 14 / 2.0 mm
2
10 m to 30 m AWG 12 / 3.5 mm
2
Switching On
600BA010 KN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stihl RE 88 and is the answer not in the manual?

Stihl RE 88 Specifications

General IconGeneral
Maximum Pressure120 bar
Water Flow Rate350-520 l/h
Power Consumption1.7 kW
Weight8.9 kg
Hose Length6 m
Max. Pressure120 bar
Max. Water Temperature40 °C
Mains Voltage230 V
Power SourceElectric