Mistblowing
The metering lever on the SR 450 must
be closed when operating in the
mistblowing mode – see dusting and
spreading mode.
N Adjust discharge rate with the
metering knob – see "Metering
Unit".
N Open the valve lever – see
"Metering Unit".
Different baffle screens can be fitted to
alter the shape and direction of the spray
for accurate application of the solution.
Conical screen
Spray is finely atomized – short, broad
and dense spray mist.
Deflector screen
Diverts spray upwards – for under-leaf
treatment of low-growing crops.
Dual defelector screen
Splits the spray in two – allows two
closely planted rows to be treated in one
pass.
Emptying the solution container
N Close the valve lever.
N Shut off the engine – see "Starting /
Stopping the Engine".
N Turn the metering knob (1) to
position "E" and collect the
remaining solution in a suitable
container.
Cleaning the solution container
N Rinse and clean the solution
container and hose system with
clear water.
N Dispose of remaining spray solution
and rinsing liquid in accordance with
local environmental requirements –
follow maker's instructions.
N Allow the machine to dry with the
cap removed.
Working
372BA006 KN
372BA007 KN
372BA008 KN
After Finishing Work