5 Configuration
5.1 Overview configuration commands
Each configuration command has to be dialed en-bloc from the ISDN phone. Enter
the configuration dial number, go off hook and go on hook.
00000101xxx
Set-up first MSN xxx for line 1
00000111xxx
Set-up second MSN xxx for line 1
00000121xxx
Set-up third MSN xxx for line 1
00000102xxx
Set-up first MSN xxx for line 2
00000112xxx
Set-up second MSN xxx for line 2
00000122xxx
Set-up third MSN xxx for line 2
(The MSN xxx may consist of 1...20 digits)
000002011
Barring incoming calls for line 1
000002021
Barring incoming calls for line 2
000002010
Release barring of incoming calls for line 1
000002020
Release barring of incoming calls for line 2
00000103ddmmyyhhmm
Set-up date and time
00000104yy
Set-up year only
(dd=day; mm=month; yy=year; hh=hour; mm=minute)
00000980
Reset all parameters to factory default
6 Operation Mode
The TA+P2I can only be used in „multipoint“ operation mode.