Parameter list software .112
MASTER PASSWORD
All passwords can be edited through param-
eterisation. If you don't remember a pass-
word, you can still parameterise the control-
ler and look up and/or edit the password
via a master password. To do that, follow
these steps:
1. Switch off power supply (disconnect from
mains or switch off power supply unit)
2. Press buttons UP, DOWN and SET at
the same time and switch on power supply
again.
3. Now, a ("Challenge") number will be dis-
played for approx. 5s.
In no case disconnect the controller from
power supply now. Otherwise, the number
will become invalid. Using this number, you
can call our sales staff, phone +49 711
68661-0 to request the master password
("Response"). Enter this master password in
the 1st control level in PA.
Important: Even if you remember the pass-
word, you must enter the master password
here. If the password is accepted, you will
enter the parameter selection levels and all
passwords will be deactivated. By pressing
the SET button (display ---) you can switch
to the relevant parameter level.
Now, the master password is no longer re-
quired. The passwords will remain deactivat-
ed until the controller is disconnected from
power supply again. In case you leave the
parameter level now, simply press the SET
button in PA in order to access the parame-
ter selection levels again.
Para-
meter
Description of function Setting range
T30
On-time relay function B: light 2 (lower 16 bit)
T31
On-time relay function B: light 2 (upper 16 bit)
T32
On-time relay function C (lower 16 bit)
T33
On-time relay function C (upper 16 bit)
T34
On-time relay function D (lower 16 bit)
T35
On-time relay function D (upper 16 bit)
T36
On-time relay function E (lower 16 bit)
T37
On-time relay function E (upper 16 bit)
T38
On-time relay function F (lower 16 bit)
T39
On-time relay function F (upper 16 bit)
T98
Reset operating hours 0: -
1: reset
0
T99
Password for T-level -99 … 999 0
The operating time is calculated as follows: Operating time (in minutes) = 65536 * T11 + T10.
Parameter T98 resets the counters for all operating times (except for T10 and T11). It depends on the setting of parameter L42. The
return value is set back to “0” automatically.
EC level (Reserved for internal use)
The level is accessible only via the ST bus.