CHART 2 (GRILL)
FAULT FINDING
SPARKING STARTS
TURN CONTROL KNOB
TO GRILL POSITION,
OPEN TOP DOOR.
GAS LIT AT GRILL
CHECK FOR 230V AT
GRILL SWITCH OUTPUT.
CHECK FOR 230V AT C ON
PRESSURE SWITCH AND
LOGIC CONTROL PCB.
CHECK FOR 230V FROM
GRILL SWITCH THROUGH
DOOR SWITCH TO L3 ON
LOGIC CONTROL PCB.
CHECK WIRING FROM
GRILL SWITCH THROUGH
DOOR SWITCH TO L3
ON IGNITION UNIT
HAS FAN STARTED?
NEON INDICATOR
LIGHTS UP
FAN STARTS
REPLACE LOGIC CONTROL
PCB. SEE ‘SERVICING
INSTRUCTIONS’.
RECTIFY WIRING OR
DOOR SWITCH
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
24