FAULT FINDING
SPARKING STARTED.
NEON INDICATOR NOT LIT. NO GAS AT BURNER.
BRIDGE FROM āCā ON PRESSURE SWITCH, TO L1
OR L2 ON LOGIC CONTROL PCB, WITH A SUIT-
ABLE DOUBLE ENDED TEST LEAD
NEUTRAL WIRE TO SOLENOID, OR
SOLENOID FAULTY.
GO TO CHART 2 (GRILL) OR CHART
3 (MAIN OVEN) OR CHART 5 (TOP
OVEN.
SOLENOID OPERATES WITH AUDIBLE CLICK
COOLING FAN STARTS OPERATING
REMOVE BACK FROM APPLIANCE, SWITCH ON
POWER AND SET PROGRAMMER TO MANUAL.
TURN CONTROL KNOB TO OVEN OR GRILL POSI-
TION AND OPEN THE OVEN DOOR.
CHART 4
NO
NO
YES
YES
YES
YES
YES
28