EasyManua.ls Logo

STRAXGAS Theme 22 User Manual

Default Icon
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Theme 22 Issue 2.1 09/07/01 Page 1 of 12
Appliance data:
Type of gas : Natural gas (G20) Cat. I
2H
Propane gas (G31) Cat. I
3P
Injector size : 7 x 0.80 (2 off) 7 x 0.62
Injector marking : 80 62
Gross heat input (high setting) : 10.2kW (34,800Btu/h) 10.0kW (34,200Btu/h)
Gross heat input (low setting) : 4.4kW (15,000Btu/h) 3.5kW (12,000Btu/h)
Supply pressure : 20mbar (8in.w.g.) 37mbar (14.8in.w.g.)
Appliance test point pressure (cold) : 18.0mbar (± 1.0mbar) 36.0mbar
Minimum flue diameter : 175mm (7in.) 175mm (7in.)
Minimum effective height of chimney : 3m (10ft.) 3m (10ft.)
Ignition : Piezo Piezo
Spark gap : 3.0mm min., 4.5mm max. 3.0mm min., 4.5mm max.
Dimensions:
Width over frame excluding trims : 624mm
Height including frame : 585mm (534mm Lowline Version)
Depth : 223mm
Shipping weight : 42kg
Country of destination : United Kingdom
& Irish Republic
This appliance has been assessed by a Government appointed Notified Body and shown to meet the
'Essential Requirements' of the European Gas Appliance Directive.
The Directive lays down requirements for the safety of the appliance, together with its design,
construction, and use of materials. It also requires the production process to be covered by an
approved and monitored system of quality assurance.
Mandatory requirements
Straxgas fires must be installed with due regard to the following mandatory regulations:
The relevant British Standard installation specifications and codes of practice, and Building Regulations
issued by the Department of the Environment, and Building Standards (Scotland) Consolidated
Regulations issued by the Scottish Development Board.
Gas Safety (Installation and Use) Regulations.
Failure to install this appliance correctly could lead to prosecution and render the guarantee
invalid.
Attention is drawn to the latest edition of the following standards:
BS1251, Specifications of open-fireplace components.
BS5440, Part 1 Specification for installation of flues.
BS5440, Part 2 Specification for installation of ventilation for gas appliances.
BS5482, Part 2 LPG, installations in permanent dwellings.
BS5871, Part 2 Installation of decorative fuel effect gas appliances.
BS6891, Specification of low pressure gas pipework
BS8303, Replacing CP403.
This Straxgas appliance is an inset live fuel effect gas fire and must only be installed by a
competent person (e.g. a C.O.R.G.I. member) in accordance with these installation instructions.
This appliance must be installed in accordance with the rules in force, and used only in a
sufficiently ventilated space. Consult these instructions before installation and use of this
appliance.
An airbrick or similar fresh air inlet must be fitted in the room in which the fire is
installed, and must have an area not less than 18 sq.cm. (2.8 sq.in.). This fresh air inlet
must not be blocked or restricted in any way.
The air vent must be either direct to outside air or to an adjacent room which itself has a vent
direct to outside air of at least the same area.
Additional purpose made air ventilation is not normally required.
Ventilation must be provided in accordance with the rules in force.
Division of Legge Fabheat Ltd.
Longfield Road, Leamington Spa, Warks. CV31 1XB
Tel. (01926) 882233 Fax. (01926) 450846 Email: info@straxgas.co.uk
Re
g
istered in En
g
land No 500091
INSTALLATION AND SERVICING INSTRUCTIONS FOR THE STRAXGAS
THEME 22" WITH 22" ECOTECH BURNER
(To be left with the appliance)
IE & Northern Ireland
GB
Question and Answer IconNeed help?

Do you have a question about the STRAXGAS Theme 22 and is the answer not in the manual?

STRAXGAS Theme 22 Specifications

General IconGeneral
BrandSTRAXGAS
ModelTheme 22
CategoryIndoor Fireplace
LanguageEnglish

Summary

Mandatory Installation Requirements

Installation Regulations and Standards

Covers mandatory installation regulations, British Standards, and Building Regulations.

Gas Safety and Competent Installation

Emphasizes Gas Safety regulations and the need for installation by a competent person.

Ventilation Requirements

Details essential ventilation requirements for safe operation of the appliance.

Preparation and Site Requirements

Pre-Installation Checks

Ensures compatibility of gas type/pressure and inspects chimney condition.

Location and Clearances

Defines suitable installation locations and necessary clearances from combustible materials.

Installing the Fire

Site Preparation and Components

Instructions for preparing the hearth, clearing debris, and listing supplied items.

Installation Procedures

Gas Connection and Assembly Sequence

Steps for connecting the gas supply and assembling the convection box.

Fret Options and Wire Fixing Kit

Details available frets and the optional wire fixing kit for installation.

Ceramic Block and Coal Warning

Warning about using only approved ceramic blocks and coals for safety.

Installation Details

Wire Fixing Kit Operation

Detailed instructions for using the optional wire fixing kit to secure the unit.

Fire Type Dimensions

Provides specific dimensions for the Theme 22 fire type.

Builder's Opening Requirements

Standard and 4-Sided Opening Diagrams

Illustrates builder's opening dimensions for standard and S146H models.

Fitting Restrictor Plate and Flange

Shows how to fit the restrictor plate and securing flange for S146H.

Final Assembly

Burner, Gas Connection and Ceramics

Steps for securing the burner, connecting gas, and handling ceramic components.

Placing Coals and Fitting Trim

Instructions for arranging coals and fitting optional canopy trim.

Coals, Testing, and Lighting

Coals Placement and Leak Testing

How to place coals and perform gas soundness and pressure tests.

Lighting Procedure and Controls

Explains control symbols and the step-by-step process for lighting the fire.

Operation and Safety Checks

Flame Adjustment and Shut-off

How to adjust flame height and turn the fire off.

Combustion Product Spillage Test

Procedure for testing spillage of combustion products and handling extraction fans.

User Instruction Handover

Guidance for installers on user explanation, sensors, and warning labels.

Maintenance, Cleaning, and Parts

Servicing, Chimney Sweeping, and Parts

Recommendations for servicing, sweeping, and ordering spare parts.

Ceramic Care, Burner Removal, and Cleaning

How to clean ceramics, remove burner/box, clean exterior, and protect finish.

Component Replacement

Gas Tap, FSD, Piezo Igniter Replacement

Detailed steps for replacing the gas tap, FSD, and piezo igniter unit.

Component Replacement and Diagrams

Injector Replacement and Reassembly

Steps for replacing main injectors and reassembling the appliance.

Burner Underside Diagrams

Technical diagrams of the burner underside for natural gas and propane versions.

Ignition and Spare Parts

Ignition & Pilot Assembly Replacement

Procedure for replacing the ignition and pilot assembly.

Outline Drawing and Spare Parts List

Provides appliance outline dimensions and a list of available spare parts.

Trim Options and Dimensions

Theme 22 Trim Variations

Details the available trim options for the Theme 22 appliance.

Convection Box and Trim Dimensions

Specific dimensions for the convection box and various trim types.

Manufacturer Liability Disclaimer

Legal disclaimer regarding installation and operation liability.