10
5 FAILURE AND TROUBLESHOTTING
NO. Code.
Failure Troubleshoong
1
LP
Water shortage
p
rotecon
f
ailure
Related to F002, when the pump reaches the water shortage protecon
value, it will enter the protecon state (check whether the water source
is short of water).
2
0C
O
ver
t
emperature
Related toF010, the temperature is higher than the over-temperature
protecon value, and the protecon state is eected (check whether the
temperature of the radiator is too high).
3
LL
Connuous
o
peraon
p
rotecon
Related to F017, when the connuous running me of the water pump
reaches the protecon value, it enters the protecon state.
4
LU
L
ow voltage
Related to F020, the voltage is lower than the low voltage protecon
value, and the protecon state is eected (check the power supply
voltage value).
5
OU
Over voltage
Related to F021, the voltage is higher than the overvoltage protecon
value, and enter the protecon state (check the power supply voltage
value)
6
0CP
O
verpressure
p
rotecon
When the water pressure of the pipeline exceeds the maximum range of
the pressure sensor, the over-pressure protecon will be displayed
(check whether the water pressure exceeds 1Mpa).
7
EAA
C
ommunicao
n
Failure
The communicaon between the drive board and the display board is
interrupted and enters the protecon state (check whether the
connecon cable is plugged in rmly)
8
EH
M
otor blocked
1. Caused by motor insulaon (test the insulaon value of motor coil);
2. The impeller is stuck (check if there is any foreign maer inside the
pump body, and whether the impeller is stuck)
9
EP
M
otor Phase
F
ailure
1.Poor welding of coil lead wire (repair welding point);
2. The wire terminal falls o or has poor contact (replace the terminal or
drive plate);
3. Coil damage (replace coil)