10
5 FAILURE AND TROUBLESHOTTING
NO. Code.
Failure Troubleshoong
1
LP
rotecon
ailure
Related to F002, when the pump reaches the water shortage protecon
value, it will enter the protecon state (check whether the water source
is short of water).
2
0C
ver
emperature
Related toF010, the temperature is higher than the over-temperature
protecon value, and the protecon state is eected (check whether the
temperature of the radiator is too high).
3
LL
peraon
rotecon
Related to F017, when the connuous running me of the water pump
reaches the protecon value, it enters the protecon state.
4
LU
ow voltage
Related to F020, the voltage is lower than the low voltage protecon
value, and the protecon state is eected (check the power supply
voltage value).
Related to F021, the voltage is higher than the overvoltage protecon
value, and enter the protecon state (check the power supply voltage
6
0CP
verpressure
rotecon
When the water pressure of the pipeline exceeds the maximum range of
the pressure sensor, the over-pressure protecon will be displayed
(check whether the water pressure exceeds 1Mpa).
ommunicao
The communicaon between the drive board and the display board is
interrupted and enters the protecon state (check whether the
connecon cable is plugged in rmly)
8
EH
otor blocked
1. Caused by motor insulaon (test the insulaon value of motor coil);
2. The impeller is stuck (check if there is any foreign maer inside the
pump body, and whether the impeller is stuck)
9
EP
otor Phase
ailure
1.Poor welding of coil lead wire (repair welding point);
2. The wire terminal falls o or has poor contact (replace the terminal or
drive plate);
3. Coil damage (replace coil)