Operation
2. Preparing for Operation
Position
generator
Position generator in accordance with the instructions given in
“Installation & Initial Set-up, Step 4: Select a Suitable Site” of this
manual.
Operate outside only, on dry, level ground with adequate clearance and
ventilation.
WARNING: Carbon monoxide poisoning hazard
Generators give off carbon monoxide exhaust, a poisonous gas that can kill. You
CANNOT smell it, see it, or taste it. ONLY run generator OUTDOORS and away
from air intakes. NEVER run generator inside any enclosed or semi-enclosed
spaces, including homes, garages, basements, sheds, boxes, pick-up truck beds,
RVs, or boats. These spaces can trap poisonous gases, EVEN if you run a fan or
open windows. Carbon monoxide exhaust is given off whether you are using petrol,
natural gas, or propane to power the generator.
Ground
generator
Make sure the generator is grounded in accordance with instruction
given in “Installation & Initial Set-up, Step 5: Grounding the
Generator”
of this manual.
WARNING: Electric shock hazard
Always ensure generator is properly grounded to prevent electrical shock.
Perform
scheduled
maintenance
as needed
Make sure that any regular maintenance has been performed as
prescribed in this manual in the “Maintenance & Repair” section.
1. Refer to the engine owner’s manual for engine maintenance
instructions.
2. Make sure battery is charged. Charge as needed according to your
battery manufacturer’s instructions.
Check/add
oil
Check the oil level using the dipstick and add oil as needed.
Using a funnel, add oil up to the FULL mark on the dip stick with the
recommended oil type for your engine and expected ambient conditions.
(See engine Owner’s Manual for oil type and capacity, and more detailed oil
check/fill instructions.)
WARNING: Burn hazard
Never open oil port while engine is running. Hot oil can spray over face
and body.
˙
Notes:
o Low oil shutdown feature prevents the generator from starting
without sufficient oil.
o Engine is shipped without oil. You must add oil before first use.
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to:
Check engine oil level every time you refuel the engine.
Change oil after the first 30 operating hours, and at least every
50 operating hours thereafter, or as directed in engine owner’s
manual.
Check/fill
petrol tank
Check the petrol level in the generator's tank. If needed, fill tank with
fresh unleaded petrol from a portable container, after first reading the
warnings and instructions below.