OIL ALERT LIGHT This light will come on when the oil level is to low and stop the machine
to protect it. It will also prevent the machine from starting if no oil is
added .The machine will not start until the oil has been topped up.
Machine oil should be changed every 30 to 40 hours . Not just topped up
all the time. Make sure the generator is level when possible and oil is full
to where the oil is just starting to run back out the hole.
VOLTMETER This should read 240v when the machine is running.
HOUR METER This meter informs the user of four (4) things
1. The frequency of the voltage – 50 to 55 Hz.
2. The time the machine has been running.
3. The total machine running hours since purchase.
4. On the 3.5KVA model – The voltage output of the machine.
OVERLOAD This switch will stop the machine if it has been running at total
PROTECTION capacity for 15 minutes OR is used at 10% above its rated capacity
CUT-OFF SWITCH
EARTH RETURN This switch will stop the machine if there is an unbalance in the
SWITCH voltage. This will help stop electrocutions.(
8.5 & 12.0KVA models only)
BATTERY (((((((((((((((
Bhould be turned off when generator not in use(switch!!!!!!!!!!!!!!!!!
ISOLATION SWITCH should be in down position).
BATTERY Suggestion – use a 1A trickle battery charger to keep the
battery conditioned when not in use.
REMOTE CONTROL Must be allowed to have a 10 second interval between when the
buttons are pressed .So as to prevent damaging the remote unit
LOAD When generator is running try and keep a load of
approximately 25% of the machine capacity at all time.
SPARK PLUGS The following brands are recommended
1. Champion – N11Y, N11YC, UN12Y.
2. Bosch – W8DY, W8DCO.
3. NGK – BP6E.
FUEL TAP Turn off the fuel supply with the tap when transporting the machine.