Maintenance & Repair
Inspect and maintain your generator as specified below in order to keep it in safe and optimal
working order. Follow all safety rules and recommended maintenance steps.
WARNING
ALWAYS shut off the engine, disconnect the spark plug(s) and discharge the capacitor
before cleaning, adjusting, or servicing the generator. Make sure all guards and shields
are replaced before using.
Maintenance & Repair
Follow safety
rules
Read and follow these safety rules whenever you will be servicing the
generator:
Turn off generator. Always turn off generator and remove spark plug(s)
or spark plug wire(s) before working on the engine or generator to
prevent accidental starting.
Replace guards. Make sure all guards and shields are replaced after
servicing the generator.
Repair. Major service, including the installation or replacement of parts,
should be performed only by a qualified electrical service technician.
Obtain factory approved parts from your place of purchase.
Replacement parts. If a part needs replacement, only use factory
approved repair parts. Replacement parts that do not meet specifications
may result in a
safety hazard or poor operation of the generator and
will void the warranty.
your place of
purchase.
Perform engine maintenance as specified in the engine owner’s
manual.
Engine maintenance items include:
1. Changing oil and oil filter if fitted.
2. Air filter check/replacement.
3. Spark plug cleaning and replacement.
4. Fuel filter check/replacement.
5. Fuel tank cleaning.
Check
receptacles
Check receptacles before each use to make sure they are not cracked
or broken.
If a receptacle is cracked or otherwise damaged, do not use until replaced
with an authorized factory part. Using cracked or damaged receptacles can
be both dangerous to the operator and destructive to the equipment.
Inspect fuel
system /check for
leaks
Inspect the fuel system and check for leaks on a regular basis.
1) Inspect the entire fuel system. Look for: signs of leaks or
deterioration ,chafed or spongy fuel hose, loose connections, loose
or missing fuel hose clamps, damaged petrol tank, or defective
petrol shut-off valve.
Check RCD
(if equipped)
Once a month, test the Residual Current Device(RCD) to protect
against electrical shock due to failure of the RCD.(Only for Those
models equipped with RCD-See the “Specifications” section.)
Note: The generator head is brushless and maintenance free. The bearing is a heavy-duty