S!
REMOTE CONTROL MANUAL
1. Active Working Status:
1) Start: Push ON button in the remote panel, the remote control receives the start signal
and check the status of generator automatically.
If the generator is working, the remote control will keep idle;
If the generator is off, the remote control will turn off the carburettor magnetic valve
(if available)and start the engine of generator;
2) Stop: Push OFF button in the remote panel, the remote control receives the stop signal
and checks the status of generator automatically.
2. Operations:
1)Pull the choke out and leave out.
2)Push “ON ”remote button to start.
3)Push “OFF ” remote button to turn off .
3. Technical Specifications
Caution
At the disturbance of same frequency, the remote distance will be shorten into 1 meter.
4.
Repair and Maintenance
If the generator remains in storage for a period of time, the battery will require charging.
Content
Unit
Specification
Size of Remote Control
mm
85*55*25
Rated Working Voltage
V
12
Idle Current
MA
3.5
Max Tolerant Voltage
V
280-320
Remote Control Frequency
MHz
50-60
Max Code Qty
piece
6561
Max Remote Distance
m
<50