Strobel-Switchable Functions (DC1200-AB611A)
F-290
Mode
Button "E" Seg1
Softstart ON/OFF
Button "E" Seg2
Not assigned
Button "+" Seg3
Thread trimmer
ON/OFF
Button "+" Seg4
Output M3
ON/OFF
Button ">>" Seg5
Basic position
"needle pos. 1"
Button ">>" Seg6
Basic position
"needle pos. 2"
Button "-" Seg7
Autom. Lifting
in the seam
Button "-" Seg8
Autom. Lifting
at the seam end
Setting range
00
56
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Preset at Mode 56 56 0 0 0 0 0 1 0 1
58-4 56 0 0 0 0 0 1 0 1
58-4F 56 0 0 1 0 0 1 0 1
170-22D 56 0 0 0 0 0 1 0 1
170-22FD 56 0 0 1 0 0 1 0 1
218D-TP-R 56 0 0 0 0 1 0 0 1
218D-TP; 327D
325-40D-TP
56 0 0 0 0 0 1 0 1
310D; 3100D 56 0 0 0 0 0 1 0 1
310D-R; 3100D-R 56 0 0 0 0 1 0 0 1
810 56 0 0 0 0 1 0 0 1
VEB100-1 56 0 0 0 0 0 1 0 1
VEB100-1F 56 0 0 1 0 0 1 0 1
VEB100-1RF 56 0 0 1 0 1 0 0 1
VEB100-2 56 0 0 0 0 0 1 0 1
VEB100-2F 56 0 0 1 0 0 1 0 1
VEB100-2RF 56 0 0 1 0 1 0 0 1
VEB100-3 56 0 0 0 0 0 1 0 1
VEB100-3F 56 0 0 1 0 0 1 0 1
VEB100-3RF 56 0 0 1 0 1 0 0 1
VEB100-4 56 0 0 0
0 0 1 0 1
VEB100-4F 56 0 0 1 0 0 1 0 1
VEB100-5 56 0 0 0 0 0 1 0 1
VEB100-5F 56 0 0 1 0 0 1 0 1
VEB100-7 Ausf. 1 56 0 0 0 0 0 1 0 1
VEB100-7 ab Ausf. 2 56 0 0 0 0 0 1 0 1
VEB100-7 ab Ausf. 3 56 0 0 0 0 0 1 0 1
Stand: 11.02.2019 - PT_AB611A_DC1200_190211
Explanation:
0 = Off
1 = On
"Control"

Table of Contents

Other manuals for Strobel VEB100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Strobel VEB100 Series and is the answer not in the manual?

Strobel VEB100 Series Specifications

General IconGeneral
BrandStrobel
ModelVEB100 Series
CategorySewing Machine
LanguageEnglish

Related product manuals