BULB INSTALLATION
CAUTION:OBSERVEALLSAFETYPROCEDURES.Putontheprotectiveface
mask.Wearcleancottonglovestopreventmarkingthequartzenvelopeofthebulbwithngerprints.
REMOVE THETOP COVER of the lamphouse by removing the four Holt head
(tamperproof)screwswiththespecialscrewdriverprovided.
NOBULBADAPTERSarerequiredtoinstallthe2000wattbulbintheXenonSuper
Trouperlamphouse.Componentsandadaptersrequiredtoinstallthe1000wattor1600wattbulb
inthelamphouseareavailableinanoptionalAdapterKit(PartNo.
7201192)
.SeetheBulbAdapter
illustrationonthefacingpageforthecorrectadaptersandmethodofassembly.
DISMOUNTANDREMOVEthefrontbulbmountingringassemblyfromtheairduct
castinginfrontofthereectorandreplaceitwiththesmallerbulbsupportyokecastingincludedin
the7201192BulbAdapterKit.Installthe65148000cathodeclampinplaceofthestandard2kW
clamp.Removetherearbulbsupportcolletassembly(nylonrodandbrasssocket)fromthebulbfocus
assemblybehindthereectorandreplaceitwiththecolletassemblyincludedintheBulbAdapterKit.
ASSEMBLETHEREQUIREDADAPTERStothe1000or1600wattbulbpriorto
insertingthebulbintothelamphouse.Beverycarefulnottoapplyanystrainonthequartzenvelope
wheninstallingadapters.
Handlethebulbbyitsmetalendcapsonly.Screwthethreadedcathode
adapterontothenegativestudsoitseatsrmlyagainsttheshoulderofthecathode(-)endcap.
Applytorqueusingthepinsonthecathodeendcap.Sliptheanodeadapterwithsetscrewoverthe
positivestud,uptotheshoulderoftheanode(+)endcap.Tightenallfastenerssecurelytoinsure
agoodelectricalconnection.
REMOVETHEPLASTICPROTECTIVECOVERfromthexenonbulbonlyifnec-
essary.Insertthebulbthroughthetopofthelamphouse,betweenthereectorsupportandthefront
casting.Passtheanode(+)endofthebulbthroughtheholeinthereector,takingcarenottotouch
thesurfaceofthereector.
INSERTTHEANODEADAPTERSTEMof1000and1600wattbulbsintotherear
supportcollet.Thestemmustbeinsertedintothesocketasfaraspossibletopermitfullfocustravel
ofthebulb.Placethestemofthecathodeadapterintofrontbulbsupportyoke,pivottheretaining
platetoitsclosedposition,andtightenthe(2)thumbscrews.Tightenthesocketheadclampingscrew
intheanodecontactsecurelytoinsureagoodelectricalcontact.
INSTALLTHECATHODELEADCONTACTovertheendofthecathodeadapter
uptotheshoulderofthecontactandtightentheclampingscrewsecurely.Dresstheleadinfrontof
theairducttominimizetheshadow.
XST/009
1000&1600WattBulbInstallation