MAINTENANCE
THEXENONSUPERTROUPERSPOTLIGHTrequiresverylittlemaintenanceto
keepitingoodworkingorder.
THEREFLECTORandheatlterglassshouldbecleanedperiodicallywithaclean,
soft,lintfreeclothtoremoveanydustfromthereectivesurface.Do notuseabrasivecleaners.
CHECKALLELECTRICALCONNECTIONSperiodicallyfortightness,especially
thebulbconnectionsandotherleadsintheDCcircuit.
THEXENONLAMPHOUSErequiresnolubricationotherthantheblowermotor.This
shouldbelubricatedwithtwoorthreedropsofnon-detergentoilateachoilholeeverysixmonths.
Thelamphousecovermustberemovedtoexposetheoilholes.
THEXENONBULBshouldbecheckedoccasionallyforpresenceofforeignmaterial
onthequartzenvelope.Anydirtorotherforeignmaterialmustberemovedimmediately.CAUTION:
Observeallsafetyprocedureswhenworkingaroundtheexposedbulb.
THEINSIDEOFTHELAMPHOUSEandtheblowershouldbecleanedperiodically,
dependingonthedustconditionsateachinstallation.Theblowerrequirescleaningtoremovedustbuild
upwhichaccumulatesoveraperiodoftime.Keeptheairinletgrillecleantopermitfreeairow.
ANARCSTABILIZATIONMAGNETismountedtothebaseofthelamphouse
belowthereectorandisrequiredbyxenonbulbmanufacturersforthecorrectoperationofthe
2000watthorizontalbulb.
Ifremovedforanyreason,itmustbereplacedwiththeNORTHseeking
pole(unpainted)towardtheright(operator’s)sideofthelamphouse.Thepresenceofthismagnetis
notdetrimentaltotheoperationof1000or1600wattbulbs,ifusedinplaceofthe2000wattbulb.
THEOPTICALSYSTEMLENSESmustbekeptcleantopreventanylightreduc-
tionintheprojectedspot.Togainaccesstothelenses,tightenthehorizontalswingandverticaltilt
lockingclamps,andremovethecolorboomerangandopticalsystemhousing.
CLEANTHEPROJECTIONLENSandlargelenswithanycleanerapprovedforuse
oncoatedprojectionlenses.Iftheprojectionlensisremovedforcleaning,notethedirectionofthe
lenswhenreinstalling.Thelenstubeismarkedwitharrowsindicatingtheendnearesttheiris.
WHENTRANSPORTINGthespotlight,itisrecommendedthatthexenonbulbbe
removedandplacedinitsoriginalshippingcartonwiththecoverontoinsureagainstbreakage.If
thespotlightisequippedwiththestandard2kWbulbshockmount,theunitmaybetransportedwith
thebulbinstalled,assumingreasonablecautionisexercised.Undernocircumstancesshouldtheunit
bemoveduntilthebulbhascooledtoroomtemperature.
XST/018