Reduced light output.
1. Normal bulb aging. Increase output current. DO NOT EXCEED MAXIMUM CURRENT
SPECIFIEDBYBULBMANUFACTURER.
2. Soiledreector.Cleanusingcommercialglasscleaner.USENOABRASIVES.
3. Soiledheatlter,projectionlensorlargelens.Cleanasrequired.
4. Bulbsealleakage.Checkbulbenvelopeforblue/whitediscoloration;replaceasrequired.
Extremely long duration between ignition pulses.
1. LowDC“NoLoad”(opencircuit)voltagefromxenonpowersupply.Check“NoLoad”voltage;
seepowersupplymanual.
2. Defectivesparkgap.A“Ping”soundisnormal;excessive“Hissing”isabnormal.Adjustor
replaceifdefective.
3. LowACvoltagetolamphouse.Checkfor115V.ACatJ2-1&J2-2;ifbelow95volts,check
stepdownorisolationtransformerinxenonpowersupply.Seepowersupplymanual.
Color gels burning or fading prematurely.
1. Bulbfocusedto“hotspot.”Refocusbulbtoateldwithirisfullyopenandspotsizecontrol
handle(“trombone”)fullyforward.
2. Heatlterglassreversedorpeeled.Checkforcoatedsurfacetowardbulb;replaceifcoating
peeled.
3. Reectorcoatingpeeled.Replaceifdefective.
XST/025
NOTICE
The Strong switching-type Xenon Power Supply employs solid
state circuitry requiring sophisticated diagnostic equipment not
generally available to eld service personnel. If an ignition problem
in the TROUBLE CHART section is traced to this unit, contact an
authorized Strong Dealer for further information.