Reduced light output.
1. Normal bulb aging. Increase output current. DO NOT EXCEED MAXIMUM CURRENT
SPECIFIEDBYBULBMANUFACTURER.
2. Soiledreector.Cleanusingcommercialglasscleaner.USENOABRASIVES.
3. Soiledheatlter,projectionlensorlargelens.Cleanasrequired.
4. Bulbsealleakage.Checkbulbenvelopeforblue/whitediscoloration;replaceasrequired.
Extremely long duration between ignition pulses.
1. LowDC“NoLoad”(opencircuit)voltagefromxenonpowersupply.Check“NoLoad”voltage;
seepowersupplymanual.
2. Defectivesparkgap.A“Ping”soundisnormal;excessive“Hissing”isabnormal.Adjustor
replaceifdefective.
3. LowACvoltagetolamphouse.Checkfor115V.ACatJ2-1&J2-2;ifbelow95volts,check
stepdownorisolationtransformerinxenonpowersupply.Seepowersupplymanual.
Color gels burning or fading prematurely.
1. Bulbfocusedto“hotspot.”Refocusbulbtoateldwithirisfullyopenandspotsizecontrol
handle(“trombone”)fullyforward.
2. Heatlterglassreversedorpeeled.Checkforcoatedsurfacetowardbulb;replaceifcoating
peeled.
3. Reectorcoatingpeeled.Replaceifdefective.
XST/025
NOTICE
The Strong switching-type Xenon Power Supply employs solid
state circuitry requiring sophisticated diagnostic equipment not
generally available to eld service personnel. If an ignition problem
in the TROUBLE CHART section is traced to this unit, contact an
authorized Strong Dealer for further information.