Installation Instructions
For Showermate Shower
Booster Pumps
1.5 bar Single, 1.5 bar Twin, 2.0 bar Twin
INDEX . . . . . . . . . . . . . . . . . . . . . . Page No
Product Description . . . . . . . . . . . . . . . . 1
Application . . . . . . . . . . . . . . . . . . . . . . . 1
Storage . . . . . . . . . . . . . . . . . . . . . . . . . 1
Typical Installation . . . . . . . . . . . . . . . . . 2
Pump Location . . . . . . . . . . . . . . . . . . . . 3
Pipework . . . . . . . . . . . . . . . . . . . . . . . . . 5
Pump Connections . . . . . . . . . . . . . . . . . 6
INDEX . . . . . . . . . . . . . . . . . . . . . . Page No
Electrical Installation . . . . . . . . . . . . . . . . 10
Commissioning . . . . . . . . . . . . . . . . . . . . 13
Maintenance . . . . . . . . . . . . . . . . . . . . . . 14
Technical Specification . . . . . . . . . . . . . . 16
Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Trouble Shooting Guide . . . . . . . . . . . . . 17
Environment Protection . . . . . . . . . . . . . 17
Please leave this instruction booklet with the pump as it
contains maintenance and safety information.
PRODUCT DESCRIPTION
Electric motor driven single or double-sided peripheral pump complete with an
automatic control system, consisting of flow switches and electronic controls.
APPLICATION
Showermate pumps are designed for pressure boosting applications in vented stored
water systems, inlet pressures to the pump and ambient temperatures must not exceed
the values given in the technical specifications.
This pump set must not be used for any other application without the
written consent of Stuart Turner Limited and in particular must not be
connected directly to the mains water supply.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
STORAGE
If this pump is not to be installed immediately on receipt, ensure that it is stored in a dry,
frost and vibration free location in its original packaging.

Questions and Answers

  • S
    Stacy PerezJul 28, 2025
    How to troubleshoot a Stuart Turner Water Pump that will not start?
    • P
      phayesJul 28, 2025
      If your Stuart Turner Water Pump isn't starting, several factors could be at play. First, ensure sufficient gravity flow (approximately 0.8 l/min) is reaching the fittings by checking the water level in the supply tank and making sure all stopcocks are open. Next, examine the filter for blockages and clean it if necessary. Verify the electrical supply by checking wiring connections, ensuring all switches are on, confirming the correct fuse is fitted, and checking the circuit breaker. If the motor thermotrip has activated, wait for it to auto reset and verify the duty point and run time are within the specified limits. For a faulty reed switch/PCB, consult Stuart Turner for the appropriate test procedure.
  • J
    Jose YoungAug 3, 2025
    Why does my Stuart Turner Water Pump keep running when all outlets are closed?
    • A
      Alexis BakerAug 3, 2025
      If your Stuart Turner Water Pump is running even when all terminal outlets are closed, there could be a leak in the system. Check tap washers, toilet valve washers, and pipe joints for leaks. If there are no leaks, the reed switch or P.C.B. might be faulty. Consult Stuart Turner for a test procedure.
  • P
    pcooperAug 8, 2025
    What to do if there is no hot water with my Stuart Turner Water Pump?
    • J
      Joshua MoralesAug 9, 2025
      If you have no hot water when using your Stuart Turner Water Pump, begin by venting the hot water pump of air, as the water feed may be air locked. Then, check that the boiler is switched ‘on’ and ensure the cylinder contains hot water. Finally, check the cylinder thermostat in case of a faulty thermostatic mixer valve.
  • L
    Lauren PriceAug 15, 2025
    How to improve reduced flow in a Stuart Turner Water Pump?
    • D
      david09Aug 15, 2025
      If your Stuart Turner Water Pump's flow or performance is reduced, start by cleaning the inlet strainers, if fitted. Next, check and clean the shower head spray plate according to the manufacturer's instructions. Finally, if the issue persists, isolate the pump electrically and hydraulically to locate and remove any blockages in the pipework or pump itself.
  • S
    Sara WebbAug 21, 2025
    Why does my Stuart Turner Water Pump start when all the taps are off?
    • H
      harriskimberlyAug 21, 2025
      If your Stuart Turner Water Pump starts when outlets are off, check for leaks in the system. Specifically, inspect tap washers, ball valve washers, and pipe joints.

Summary

Product Information

Application

Explains the pressure boosting applications of Showermate pumps.

Typical Installation

Pump Location

General guidance on selecting an appropriate location for the pump installation.

Pipework

General guidelines and precautions for pipework installation.

STEP 3 PUMP CONNECTIONS

STEP 4 ELECTRICAL INSTALLATION

STEP 5 COMMISSIONING

TECHNICAL SPECIFICATION AND NOISE

Technical Specifications

Detailed technical specifications for different pump models.

TROUBLE SHOOTING AND ENVIRONMENTAL PROTECTION

Troubleshooting Guide

Guide to diagnose and resolve common pump issues.

Stuart Turner Showermate Series Specifications

General IconGeneral
BrandStuart Turner
ModelShowermate Series
CategoryWater Pump
LanguageEnglish