PAGE 24 STUV 6 | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE
^
TEST REPORT
TEST REPORT NO ASFT18044
(PRELIMINARY REPORT)
TESTING LABORATORY:
Australian Solid Fuel Testing
MANUFACTURER:
Stuv
MODEL:
STUV 6
WORK REQUESTED:
Assessment of appliance to AS/NZS 4012:2014 for determination of Power Output
and Efficiency and AS/NZS 4013:2014 for flue gas emission using hardwood fuel.
ISSUE DATE:
05/06/2020
INVESTIGATING OFFICER:
Steve Marland
RESULTS:
The Stuv 6 Insert solid fuel burning appliance produced an appliance particulate
emissions factor of 0.6g/kg and an average efficiency of 62% for all burn rates,
using hardwood that complies to AS/NZS 4014.1, when tested according to joint
AS/NZS 4012, AS/NZS 4013 (2014).
CONCLUSION:
The Stuv 6 Insert solid fuel burning appliance complies with the requirement of a
combined efficiency of not less than 60% and a particulate emissions factor of not
greater than 1.5g/kg of hardwood that complies to AS/NZS4014.