PAGE 11 STUV 6 | SPECIFICATIONS & MANUFACTURER INSTALLATION GUIDE
^
FLOOR PROTECTOR
Any combustible floor beneath a fireplace must have a floor protector that also extend in
front of the appliance.
If the fireplace is installed on a concrete, masonry or non combustibe floor there is no
requirement for a floor protector.
Floor protector must be minimum 30mm thick cement sheet (excluding non combustible floor finish)
Floor protector must be minimum 9mm thick cement sheet (excluding non combustible floor finish)
COMBUSTIBLE FLOOR INSTALLATION - FIREBOX IS INSTALLED BELOW 400MM HEIGHT
COMBUSTIBLE FLOOR INSTALLATION - FIREBOX IS INSTALLED AT 400MM HEIGHT OR ABOVE
550mm
965mm
760mm
300mm
30mm cement sheet
9mm cement sheet
Combustible floor
Combustible floor
399mm or lower
400mm or higher
Finished non combustible floor
Finished non combustible floor
1030mm
1030mm
550mm
300mm