Troubleshooting Guides
600 Series
(Prior to #1810000)
8-15
#3756270 - Revision B - January, 2006
SEALED SYSTEM REPAIR PROCEDURES
Problem What To Do
Non-Operating, Inefficient, Noisy Compressor
(NOTE: To check for a non-operating compressor, a hard start
kit can be used.)
High Side Leak
Low Side Leak
Contaminated Sealed System
Example:
Burned out compressor
Excessive moisture from leak at condensate loop
Excessive moisture from leak in low side
Plugged capillary tube, etc...
Restriction
(NOTE: If restriction is due to contaminated sealed system, see
Contaminated Sealed System above.)
Overcharge
a. Capture refrigerant.
b. Replace compressor.
c. Replace filter-drier.
d. Evacuate or sweep charge system.
e. Recharge system with Virgin 134a refrigerant.
a. Capture refrigerant.
b. Repair leak.
c. Replace filter-drier.
d. Evacuate or sweep charge system.
e. Recharge system with Virgin 134a refrigerant.
a. Capture refrigerant.
b. Repair leak (if at solder joint) or replace part.
c. Back flush high side of sealed system.
d. Replace compressor.
e. Replace filter-drier.
f. Evacuate or sweep charge system.
g. Recharge system with Virgin 134a refrigerant.
a. Capture refrigerant.
b. Repair leak (if at solder joint) or replace part.
c. Back flush high side of sealed system.
d. Replace compressor.
e. Replace filter-drier.
f. Replace heat exchanger if cap tube is clogged.
g. Install a low side drier on suction line.
h. Evacuate or sweep charge sealed system.
i. Recharge with Virgin 134a refrigerant.
a. Capture refrigerant.
b. Locate and remove restriction or locate and replace part.
c. Back flush high side of sealed system.
d. Replace filter-drier.
e. Evacuate or sweep charge system.
d. Recharge system with Virgin 134a refrigerant.
a. Capture refrigerant.
b. Replace filter-drier.
c. Evacuate or sweep charge system.
d. Recharge system with Virgin 134a refrigerant.

Table of Contents

Other manuals for Sub-Zero 600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sub-Zero 600 Series and is the answer not in the manual?

Sub-Zero 600 Series Specifications

General IconGeneral
TypeBuilt-In
Energy Star CertifiedYes
Ice MakerYes
LightingLED
Door AlarmYes
Temperature AlarmYes
ConfigurationSide-by-Side
Width36 inches
Height84 inches
Water DispenserYes
ShelvesAdjustable glass shelves

Related product manuals