Page 29
Electronic Control
Integrated (
Integrated (
700-
700-
2) Series
2) Series
3-19
#3756780 - Revision D - July, 2005
Figure 3-31. Model 700TC/I-2
“ICE” & “SERVICE” Flashing = Water Valve Solenoid energized 15 Seconds, Icemaker System Disabled
NOTE: To clear this error indicator the problem must be corrected, then the unit switched OFF and back ON.
UNIT
ICE
WARMER
COLDER
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
SERVICE
Figure 3-29. Model 700TC/I-2
“EE” Displayed at Left and “SERVICE” Flashing = Freezer Compartment Thermistor (or its Wiring) Fault
NOTE: To clear this error indicator the problem must be corrected
UNIT
ICE
WARMER
COLDER
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
SERVICE
Figure 3-30. Model 700TC/I-2
“EE” Displayed at Right and “SERVICE” Flashing = Refrig. Compartment Thermistor (or its Wiring) Fault
NOTE: To clear this error indicator the problem must be corrected
ICE
UNIT
ICE
WARMER
COLDER
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
SERVICE
UNIT
ICE
WARMER
COLDER
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
SERVICE
Figure 3-32. Model 700TC/I-2
“SERVICE” Alone Flashing = Excessive Compressor Run (OR) Refrig. Evap. Thermistor (or its Wiring) Fault
NOTE: To help identify the problem, Diagnostic Mode (Covered later in this section) should be initiated.
NOTE: To clear this error indicator the problem must be corrected, then the unit switched OFF and back ON.
POSSIBLE 700-2 TALL UNIT ERROR INDICATORS
The next few pages contain diagrams illustrating what a customer may see on the LCD if there is a problem/error
with the unit. Please note the serial number breaks listed under some diagrams.
• For Model 700TC/I-2, See Figures 3-29 through 3-33
• For Model 700TR-2, See Figures 3-34 through 3-37
• For Model 700TF/I-2 and Model 700TF/I-2V, See Figures 3-38 through 3-41
UNITICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMERCOLDER
FREEZER
WARMERCOLDER
SERVICE
Figure 3-33. Model 700TC/I-2 (AFTER SERIAL #1759493)
“EC” at Right and “SERVICE” Flashing = Excessive Compressor Run with Error Codes Registered
NOTE: To clear this error indicator and error code, the problem must be corrected, then the alarm bell ON/OFF
key must be pressed and held for 15 seconds.