Planning Information 10
Electrical Requirements. For all built-in models, the
electrical supply should be located within the shaded area
shown in the illustration. Follow the National Electrical
Code and local codes and ordinances when installing
the receptacle. A separate circuit, servicing only this
appliance is required.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
75
1
/2"
(1918)
7"
(178)
6"
(152)
E
FRONT VIEW
Location of electrical supply.