Section 3
SPECIFICATIONS
14
MOTOR: (24KT A ND STAND ARD COMPRESSORS)
Type 30HP
Size 60Hz, 3 Phase, ODP, 460V, A.C. 40_C M aximum Ambient Temperature
Options: 200V to 230V and 575V
TEFC Also Availa ble
Speed 1800RPM
Starter 460V Magnetic Full Voltage
Options: 200V to 230V and 575V
Shaft Diameter 1%@8 (41.3mm)
Type 40HP
Size 60Hz, 3 Phase, ODP, 460V, A.C. 40_C M aximum Ambient Temperature
Options: 200V to 230V and 575V
TEFC Also Availa ble
Speed 1770RPM
Starter 460V Magnetic Full Voltage
Options: 200V to 230V and 575V
Shaft Diameter 1&@8 (47.6mm)
FOR 50 HZ COMPRESSORS
Type 25HP
Size 60Hz, 3 Phase, ODP, 380V, A.C. 40_C M aximum Ambient Temperature
Speed 1500RPM
Starter 380V Magnetic Full Voltage
Options: 415V
Shaft Diameter 1%@8 (41.3mm)
Type 30HP
Size 60Hz, 3 Phase, ODP, 380V, A.C. 40_C M aximum Ambient Temperature
Speed 1500RPM
Starter 380V Magnetic Full Voltage
Options: 415V
Shaft Diameter 1%@8 (41.3mm)
Type 40HP
Size 50Hz, 3 Phase, ODP, 380V, A.C. 40_C M aximum Ambient Temperature
Options: 415V
TEFC Also Availa ble
Speed 3000RPM
Starter 380V Magnetic Full Voltage
Shaft Diameter 1%@8 (41.3mm)
LUB RICATION GUIDE-- STANDARD COM-
PRESSORS
Sullair standard compressors are filled with SRF
1/4000 fluid as factory fill.
WARNING
!
Mixing of other fluids within the compressor will
void all warranties.
SRF 1/4000 fluid s hould be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or s trong oxi-
dizing gases are present in the air.
F or extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of a ll other components is still recom-
mended as indicated in the Operator’s Manual.
LUB RICATION GUIDE-- 24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which normally does not n eed to be changed. In
the event a change of fluid is required, use only Sul-
lair 24KT fluid.
WARNING
!
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullair recommends that a 24KT s ample be taken
at the first filter change and sent to the factory for

Related product manuals