Section 1
1600H T4F CAT/Perkins Addendum 1: Description
02250251-632 R01
Subject to EAR, ECCN EAR99 and related export control restrictions. 5
Description
1.1 Introduction & functional
description
This compressor is equipped with Sullair’s Condensate
Management System (CMS). This system utilizes the
waste heat from the engine exhaust to evaporate con-
densate produced when operating in after-cooled mode.
Using CMS eliminates the need to collect and dispose of
condensate.
When operating in after-cooled mode, condensate is pro-
duced by the aftercooler and separated from the air
stream in the moisture separator. A small amount of addi-
tional condensate is removed by the after filters. These
condensate streams are routed to the exhaust and driven
by system pressure. Once at the exhaust, an atomizing
nozzle is used to inject the condensate into the exhaust
stream where it is evaporated.
Figure 1-1: Discharge System with Condensate Management System
1. Aftercooler
2. After-filters
3. Moisture separator
4. Strainer
5. Blow-down valve
6. Exhaust pipe
7. Nozzle