Sullair DEX Series - User Manual

Sullair DEX Series
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Failure to follow the instructions
and procedures in this manual or,
misuse of this equipment will
VOID its warranty!
WARRANTY NOTICE
USER/SERVICE MANUAL
HEATED REGENERATIVE DRYERS
DEX SERIES
PART NUMBER:
KEEP FOR
FUTURE
REFERENCE
©
SULLAIR CORPORATION
02250195-404 R00
The information in this manual is current
as of its publication date, and applies to
compressor serial number:
and all subsequent serial numbers.
SEHIBAAA-0001

Questions and Answers

  • U
    ubrownAug 14, 2025
    What to do if my Sullair DEX shows a loss of power alarm?
    • E
      Emma JohnsonAug 14, 2025
      If you're getting a 'Loss of power alarm' on your Sullair Dryer, start by checking the control circuit fuse and replace it if needed. Also, check the PLC to see if any outputs are 'on' or if the PLC alarm LED is lit; replace the PLC if necessary. Finally, verify that the system's incoming power supply is active and restore it if it has been lost.
  • J
    Julie PowersAug 17, 2025
    How to fix high humidity alarm on Sullair DEX Dryer?
    • W
      wbaileyAug 17, 2025
      If your Sullair Dryer displays a high humidity alarm, which may come with an optional dew point monitor, you should first reset the alarm using the “Alarm Reset” push button. Then, check the heating and cooling operations by watching the regenerations, ensuring the regeneration temperatures match those in Section 3.7. Also, make sure that the dewpoint probe service valves are open.
  • B
    Brooke JonesAug 20, 2025
    What causes regeneration heater sheath over temperature failure in Sullair DEX Dryer?
    • B
      brownericAug 20, 2025
      If the Sullair Dryer shows a 'Regeneration heater sheath over temperature failure', replace the thermocouple. Also, check the regeneration blower, motor, motor overloads, and inlet filter, replacing parts as needed. If those aren't the problem, replace the temperature switch.
  • J
    joseph77Aug 23, 2025
    What to do if Sullair DEX Dryer displays blower overload alarm?
    • S
      Sandra StevensonAug 25, 2025
      If your Sullair Dryer is showing a Blower overload alarm, check the motor overload to see if it is defective. Also, check the operating conditions to see if the motor is operating overloaded due to a problem with the blower or motor bearing.
  • K
    Kevin LewisAug 27, 2025
    How to troubleshoot vessel #1 de-pressurization failure on Sullair DEX?
    • J
      jenniferramosAug 27, 2025
      If Vessel #1 fails to depressurize on your Sullair Dryer, start by checking the solenoid valves and valve actuator for correct operation. If that's not the issue, check if the depressurization muffler is plugged. If the vessel depressurized but the alarm is still on, check the pressure switch for correct operation.
  • M
    Madeline ThomasAug 30, 2025
    What to do if vessel #2 de-pressurization fails on Sullair DEX?
    • J
      Jerry WebbAug 30, 2025
      If Vessel #2 fails to depressurize on your Sullair Dryer, check the solenoid valve and the valve actuator for correct operation. Also, verify that the depressurization muffler isn't plugged. If the vessel did depressurize but the alarm is still active, check the pressure switch for proper operation.
  • W
    William HammondSep 2, 2025
    Why is vessel #1 re-pressurization failing on my Sullair DEX Dryer?
    • T
      timothy91Sep 3, 2025
      If Vessel #1 fails to re-pressurize on your Sullair Dryer, check the air actuated ball valve for correct operation. Also, check the valve actuator and the pilot solenoid valve. If the vessel re-pressurized but the alarm remains on, check pressure switch PSH-1 for correct operation.
  • M
    Michelle BrooksSep 6, 2025
    How to fix vessel #2 re-pressurization problem in Sullair DEX?
    • A
      awilliamsSep 6, 2025
      If Vessel #2 is experiencing re-pressurization issues on your Sullair Dryer, check the pilot solenoid valve for correct operation. Also, check the valve actuator. If the vessel re-pressurized, but the alarm is still on, check pressure switch PSH-2 for correct operation.
  • A
    Allison BaileySep 9, 2025
    Why is there low operating pressure during regeneration in my Sullair DEX?
    • M
      Madison PottsSep 9, 2025
      If you're experiencing low operating pressure during regeneration with your Sullair Dryer, first check the compressor to ensure it is running. Also, check all manual valves upstream of the dryer and open them as needed.

Summary

Section 1 INTRODUCTION

IDENTIFICATION PLATE

Details about the product identification plate and its importance for data.

WARRANTY CONDITIONS

Explains the terms and duration of the warranty coverage for the equipment.

Section 2 SAFETY

SAFETY INFORMATION

General safety guidelines and regulations for operating pressure vessels and equipment.

DEFINITION OF THE SAFETY SYMBOLS USED

Explains the meaning of various safety symbols used throughout the manual.

WARNINGS

Critical warnings regarding compressed air hazards, unauthorized use, and maintenance.

PROPER USE OF THE DRYER

Guidelines for the intended use of the dryer and responsibilities of the user.

INSTRUCTIONS FOR THE USE OF PRESSURE EQUIPMENT

Specific instructions for safe operation of pressure equipment.

Section 3 SPECIFICATIONS

TYPE OF CONSTRUCTION

Describes the dryer's construction and design standards.

AMBIENT CONDITIONS

Specifies the recommended ambient temperature and pressure ranges.

OPERATIONAL DATA

Provides data for adsorption, regeneration, and cooling cycles of the dryer.

PRESSURE VESSEL DESIGN AND CONSTRUCTION DATA

Details on desiccant chambers and pre/afterfilter construction per ASME standards.

PIPE MANIFOLD DETAILS

Specifies pipe sizes for wet air inlet, dry air outlet, and regeneration outlet.

ELECTRICAL DATA

Information on power supply, enclosure, and control voltages for the dryer.

TIME, PRESSURE, TEMPERATURE, AND DEWPOINT SETTINGS

Lists operational settings for adsorption, regeneration, heating, and cooling.

DIMENSIONS AND WEIGHT

Provides the physical dimensions and weight of the dryer unit.

FILTER MODELS

Identifies specific models for pre-filter, after-filter, and control air filters.

Section 4 INSTALLATION

Section 5 OPERATION

ADSORPTION

Explains the process of drying compressed air using desiccant beds.

REGENERATION

Details the process of regenerating the desiccant beds using heated air.

COOLING

Describes the cooling cycle after regeneration to prepare the vessel for adsorption.

TIME CONTROLLED VESSEL CHANGE OVER

Explains how vessel switching is managed based on a set time.

DEWPOINT CONTROLLED VESSEL CHANGE OVER (OPTION)

Describes vessel switching managed by the desiccant's dewpoint.

PANEL MOUNTED DATA DISPLAY

Information on the equipment's data display and its functions.

EQUIPMENT START UP

Procedures and checks required before starting the dryer.

EQUIPMENT SHUT DOWN

Instructions for safely shutting down the dryer for normal or emergency stops.

ID-DEX 200

Specific diagram and component list for the ID-DEX 200 model.

ID-DEX 250-300

Specific diagram and component list for the ID-DEX 250-300 models.

ID-DEX 400-600

Specific diagram and component list for the ID-DEX 400-600 models.

P&I-DEX 200-3500

Piping and instrumentation diagram for DEX 200-3500 models.

ELECTRICAL SCHEMATIC-TYPICAL EXTERNALLY HEATED

Electrical schematic for typical externally heated dryer configurations.

ELECTRICAL SCHEMATIC

Electrical schematic details and wire color coding.

Section 6 TROUBLESHOOTING

Troubleshooting Guide

Lists common symptoms, probable causes, and recommended remedies for dryer issues.

Section 7 SYSTEM MAINTENANCE

WITH YOUR DRYER ONLINE

Daily, weekly, and monthly checks for a dryer operating in service.

MONTHLY INSPECTIONS

Procedures for monthly checks of the dryer system for leaks and component operation.

QUARTERLY INSPECTIONS

Quarterly inspection tasks including checks for dirt and flange tightness.

YEARLY INSPECTIONS

Annual maintenance tasks involving replacement of valve parts and actuator inspection.

DESICCANT CHANGE OUT

Step-by-step guide for replacing the desiccant material in the dryer.

FILTER ELEMENT CHANGE OUT

Guidelines for replacing pre-filter and after-filter elements based on usage.

Section 8 TECHNICAL DESCRIPTION OF COMPONENTS

ADSORBER

Description of the adsorber vessel and its function with desiccant.

DESICCANT

Information on the type, amount, density, and size of the desiccant used.

HEATER

Details on the external regeneration heater, its construction, and electrical specifications.

VALVES

Description of inlet, switching, and purge exhaust valves used in the dryer.

ACTUATORS

Information on pneumatic actuators used for valve operation and required air pressure.

REGENERATION BLOWER

Details on the centrifugal blower used for regeneration air supply.

PRESSURE GAUGE

Information on pressure gauges for local indication and their type.

Section 9 SPARE PARTS LIST

SPARE PARTS LIST

Comprehensive list of part numbers for various dryer components and models.

Section 10 COMPONENT BULLETINS

Sullair DEX Series Specifications

General IconGeneral
BrandSullair
ModelDEX Series
CategoryDryer
LanguageEnglish